Test 2017-12-14-1-4 (ASTM F606-14a) Summary

Project Information
Project IdentifiersProject ID: 211889
DEA: 08368514
EFIS: 0813000077
DIST-CO-RTE-PM08-SBD-15-81.1/87.5&177.3/181.1
Work DescriptionCONSTRUCT AIF AND DEMOLISH EXISTING AIF IN YERMO
Location DescriptionSAN BERNARDINO COUNTY FROM 0.6 MILE NORTH OF YERMO ROAD OVERCROSSING TO 1.0 MILE SOUTH OF MINNEOLA ROAD OVERCROSSING AND FROM 1.2 MILE NORTH OF NIPTON ROAD OVERCROSSING TO 0.5 MILE SOUTH OF YATES WELL ROAD OVERCROSSING
Sample Information
Sample Taken Date12/14/2017 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing12/14/2017
Sample typeQuality Assurance A brief description of the sampleA325 Bolt Assemblies
The quantity of what the sample constitutes8 From where was the sample collectedSource
First name of sampler or witnessed byTory Last name of sampler or witnessed byMcLaurin
Title of samplerQA Inspector Laboratory sample identificationUnknown
The fabricator/manufacturer/facility nameK and J Steel Transportation Laboratory (TL) NumberUnknown
Inspector Lot Number from the Transportation Laboratory (TL) FormL67-289-17 Structure unique identifierNot set
Structure nameNot set
Material Information
Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)
Heat Number(s)100884905, 10088218, NF14102181, 100785838, 10391980, 10498480, 10433230, 10286370 Nut Mfg. Lot Number(s)20932-M58090, 26503-75065969, 24083-75063411, 17154-62130915, 391703A, 382494B, 344208B, 387411A
Washer Mfg. Lot Number(s)031357, 028700, 030986, 031793, C9744, D3960 , D3161, 7250M, Bolt SpecificationF3125 / F1852
Bolt Length(s)1-3/4", 2", 2-1/4", 2-1/2" Nut SpecificationA563 DH
Washer SpecificationF436 FinishMechanically Galvanized
Diameter/Size5/8, 3/4 Bolt Mfg. Lot Number21576-10391980, 29403-10498480, 25113-1043323
Rocap Test Requirement(s) Lubricant Requirements(s)
Test Details
DIME Sample ID: 2017-12-14-1
DIME Test ID: 2017-12-14-1-4
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2018-01-11
Test Results

Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 12/22/2017
UTM:400KIP
Temperature:72 F
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)CommentsTested By
11B387411A?\"50757225.78Nut Proof LoadBrian

General comments (publicly viewable) (Max 1000 characters): Nut Proof Load
Test Graph
Source: Partner Data Point File

Test was verified on 01/04/2018