Test 2017-12-19-1-1 (AASHTO T27-14) Summary

Project Information
Project IdentifiersProject ID: 99999
DEA: 0322222
DIST-CO-RTE-PM03-SAC,OMG-888,99,80-0.6-0.6
Work DescriptionTHIS PROJECT RECORD WAS ADDED FOR DIME TESTERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES.
Location DescriptionTHIS PROJECT RECORD WAS ADDED FOR DIME TESTERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES.
Sample Information
Sample Taken Date12/19/2017 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing12/19/2017
Sample typeQuality Control A brief description of the sampleAggregate gradation
The quantity of what the sample constitutesTEST Quantity From where was the sample collectedOther
First name of sampler or witnessed byTEST First Last name of sampler or witnessed byTEST Last
Title of samplerTEST Sampler Laboratory sample identificationLab 326120
The fabricator/manufacturer/facility nameReliance - Irwindale Transportation Laboratory (TL) NumberTL 326120
Inspector Lot Number from the Transportation Laboratory (TL) FormTEST TL Structure unique identifierNot set
Structure nameNot set
Material Information
Material TypeAggregate Source Identification (SMARA or name of Pit)326120 Source ID
The fabricator's/manufacturer's product name for the sampleTEST Fab Name The fabricator/manufacturer designation for the sampleTEST Fab Designation
The plant numberTEST Plant Number A detailed description of where the material sample was collectedAggregate
Where the material sample would have been placed if not sampledTEST Material Sample Primary Aggregate Nominal Size1/2 inch
The concrete mix design numberTEST Concrete ID Lot numberNot set
Sublot numberNot set HMA Design ID JMF3512-2017-9
Test Details
DIME Sample ID: 2017-12-19-1
DIME Test ID: 2017-12-19-1-1
Testing Lab: CT QAM - Sacramento Field Laboratory
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2017-12-26
Test Results

What type of gradation is being tested?: HMA Gradation
Does this test use 1/4 sieve? (question for HMA Gradation Type): Yes
Input Type: Calculated
Tester's full name: Clinton Edmiston
Date of test: 12/19/2017
Cumulative percent passing the 1 1/2 in. sieve:100 %
Cumulative percent passing the 1 in. sieve:100 %
Cumulative percent passing the 3/4 in. sieve:100 %
Cumulative percent passing the 1/2 in. sieve:89 %
Cumulative percent passing the 3/8 in. sieve:31 %
Cumulative percent passing the 1/4 in. sieve:31 %
Cumulative percent passing the #4 sieve:8 %
Cumulative percent passing the #8 sieve:5 %
Cumulative percent passing the #16 sieve:4 %
Cumulative percent passing the #30 sieve:3 %
Cumulative percent passing the #50 sieve:2 %
Cumulative percent passing the #100 sieve:2 %
Cumulative percent passing the #200 sieve:1.4 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 12/19/2017