Summary for Test 2017-11-30-4-2
Test performed: ASTM F606-14aProject Information
Project Identifiers | Project ID: 211226 DEA: 024E6404 EFIS: 0212000011 |
---|---|
DIST-CO-RTE-PM | 02-PLU-147-8.9/9.3 |
Award Date | 05/10/2016 |
Closeout Date | 11/12/2020 |
Work Description | REPLACE BRIDGE, GUARDRAILING, HMA, STRIPING |
Location Description | PLUMAS COUNTY ABOUT 9 MILES NORTH OF CANYON DAM FROM 0.1 MILE SOUTH TO 0.4 MILE NORTH OF HAMILTON BRANCH BRIDGE |
QA Service Level | 1 (Verified on 04/21/2016) |
Sample Information
Sample Taken Date | 11/30/2017 | Sample Unique Key | 4 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 12/04/2017 |
Sample type | Quality Assurance | A brief description of the sample | A325 Bolt |
The quantity of what the sample constitutes | 72 | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Kevin | Last name of sampler or witnessed by | Churchill |
Title of sampler | QAI | Telephone number of sampler | 510 693-3545 |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | UIS | Transportation Laboratory (TL) Number | Unknown |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L02-081-17 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
---|---|---|---|
Heat Number(s) | NF14203689 | Nut Mfg. Lot Number(s) | |
Washer Mfg. Lot Number(s) | Bolt Specification | A325 | |
Bolt Length(s) | 4" | Nut Specification | DH |
Washer Specification | F436 | Finish | HDG |
Diameter/Size | 1/2" | Bolt Mfg. Lot Number | 349424, G8338 |
Rocap Test Requirement(s) | Lubricant Requirements(s) |
Test Details
DIME Sample ID: 2017-11-30-4
DIME Test ID: 2017-11-30-4-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2017-12-14
Test Results
Number of Bolt Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 12/06/2017
UTM: 400KIP
Temperature: no data
Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Wedge Angle (deg) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|
1 | 1B | L0208117 | 1/2\" | 20850 | 92.7 | 10 | A325 | Fred |
General comments (publicly viewable) (Max 1000 characters): A325
Test Graph
Source: Partner Data Point FileTest was verified on 12/7/2017 ✔