Summary for Test 2017-11-30-10-2
Test performed: ASTM F606-14aProject Information
Project Identifiers | Project ID: 210828 DEA: 07290704 EFIS: 0712000076 |
---|---|
DIST-CO-RTE-PM | 07-LA-47-0.9/2.0 |
Award Date | 04/06/2016 |
Closeout Date | 06/25/2019 |
Work Description | RESTORE BRIDGE SEISMIC. |
Location Description | Not set |
QA Service Level | 1 (Verified on 06/03/2016) |
Sample Information
Sample Taken Date | 11/30/2017 | Sample Unique Key | 10 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 12/04/2017 |
Sample type | Quality Assurance | A brief description of the sample | A325 Fastener Assembly |
The quantity of what the sample constitutes | 644 | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | James | Last name of sampler or witnessed by | Doe |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Bay Bolt | Transportation Laboratory (TL) Number | NA |
Inspector Lot Number from the Transportation Laboratory (TL) Form | B358-119-17 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | 8746-2, 8794-02/8746-01, 8746-03, 8746-04, 8746-05, 8746-06 |
---|---|---|---|
Heat Number(s) | Nut Mfg. Lot Number(s) | 387398B, 372874A | |
Washer Mfg. Lot Number(s) | 293040, 1216-412 | Bolt Specification | A325 |
Bolt Length(s) | 1.75, 1.5, 2, 2.25, 2.5, 2.75 | Nut Specification | A563 |
Washer Specification | F436 | Finish | HDG |
Diameter/Size | .625 | Bolt Mfg. Lot Number | 777977, 756404, 352566A, 386693A, 767398, 107 |
Rocap Test Requirement(s) | Lubricant Requirements(s) |
Test Details
DIME Sample ID: 2017-11-30-10
DIME Test ID: 2017-11-30-10-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2017-12-14
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 12/05/2017
UTM: 400KIP
Temperature: 72 F
Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By |
---|---|---|---|---|---|---|---|
1 | 1B | N/A | 5/8\" | 34618 | 153.99 | Nut Proof Load | Brian |
General comments (publicly viewable) (Max 1000 characters): Nut Proof Load
Test Graph
Source: Partner Data Point FileTest was verified on 12/7/2017 ✔