Summary for Test 2017-11-30-5-2
Test performed: ASTM F606-14aProject Information
Project Identifiers | Project ID: 212854 DEA: 07342101 EFIS: 0717000244 |
---|---|
DIST-CO-RTE-PM | 07-LA-5-27.0/66.5 |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Establish standard vertical clearance. |
Location Description | In Los Angeles County, at various locations. |
QA Service Level | 1 (Verified on 10/30/2017) |
Sample Information
Sample Taken Date | 11/30/2017 | Sample Unique Key | 5 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 11/30/2017 |
Sample type | Quality Assurance | A brief description of the sample | A325 3/4 Bolt Assembly |
The quantity of what the sample constitutes | 7 | From where was the sample collected | Source |
First name of sampler or witnessed by | Tory | Last name of sampler or witnessed by | McLaurin |
Title of sampler | QA Inspector | Telephone number of sampler | 6616185971 |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Cordova Bolt | Transportation Laboratory (TL) Number | Unknown |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L67-279-17 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | N/A |
---|---|---|---|
Heat Number(s) | 11431677, 131743, DL13102379, 31727470 | Nut Mfg. Lot Number(s) | 331329B |
Washer Mfg. Lot Number(s) | 0917-617, 343Z13 | Bolt Specification | A325 |
Bolt Length(s) | 2-3/4 | Nut Specification | A563 DH |
Washer Specification | F436, F959 | Finish | Mechanically Galvanized |
Diameter/Size | 3/4 | Bolt Mfg. Lot Number | 150700A |
Rocap Test Requirement(s) | Lubricant Requirements(s) |
Test Details
DIME Sample ID: 2017-11-30-5
DIME Test ID: 2017-11-30-5-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2017-12-12
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 12/05/2017
UTM: 400KIP
Temperature: 72 F
Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By |
---|---|---|---|---|---|---|---|
1 | 1A | L67-279-17 | ?\" | 50843 | 226.16 | Nut Proof Load | Brian |
General comments (publicly viewable) (Max 1000 characters): Nut Proof Load
Test Graph
Source: Partner Data Point FileTest was verified on 12/5/2017 ✔