Summary for Test 2017-11-01-10-4

Test performed: AASHTO T269-14

Project Information

Project IdentifiersProject ID: 9999
DEA: 00000000
EFIS: 0000000000
COOP: 99999333399
MINOR: 333333
Permit Numbers: 555555 0400NRT0000
DIST-CO-RTE-PM03-SAC,OMG-888,99,80-0.6-0.6
Award DateNot set
Closeout DateNot set
Work DescriptionTHIS PROJECT RECORD WAS ADDED FOR DIME DEVELOPERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES.
Location DescriptionTHIS PROJECT RECORD WAS ADDED FOR DIME DEVELOPERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES.
QA Service Level1 (Verified on 04/05/2013)

Sample Information

Sample Taken Date11/01/2017 Sample Unique Key10
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing11/01/2017
Sample typeVerification A brief description of the sampleJMF Verification
The quantity of what the sample constitutes1 From where was the sample collectedManufacturer
First name of sampler or witnessed byScott Last name of sampler or witnessed bywith ESE
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameSNC - Mustang Asphalt Plant Transportation Laboratory (TL) NumberUnknown
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot numberNot set
Sublot numberNot set HMA Mix NumberNot set
HMA PayNo

Test Details

DIME Sample ID: 2017-11-01-10
DIME Test ID: 2017-11-01-10-4
Testing Lab: CT HQ - Sacramento Materials Management Branch Field Office
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Test Release Date: 2017-11-08

Test Results


Number of tests: 3
Input Type: Calculated
Tester's full name: Thinh Nguyen
Date of test: 11/01/2017
Percent Air Voids: 4.2 %
Percent Air Voids 2: 4.5 %
Percent Air Voids 3: 4.1 %
Percent Air Voids Average: 4.3 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 11/1/2017