Test 2017-10-24-8-3 (CTM 670-December 2013) Summary

Project Information
Project IdentifiersProject ID: 209384
DEA: 04264094
EFIS: 0400000735
COOP: 042531
DIST-CO-RTE-PM04-,SON--
Work DescriptionNot set
Location DescriptionNot set
Sample Information
Sample Taken Date10/24/2017 Sample Unique Key8
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/27/2017
Sample typeQuality Assurance A brief description of the sample8 Rebar with Bartec Coupler
The quantity of what the sample constitutes150 From where was the sample collectedJob Site
First name of sampler or witnessed byMelvin Last name of sampler or witnessed byDumlao
Title of samplerASR Laboratory sample identificationUnknown
The fabricator/manufacturer/facility nameHarris Salinas Rebar Transportation Laboratory (TL) NumberUnknown
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierNot set
Structure nameNot set
Material Information
Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateUltimate Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerNucor
Coupler ManufacturerDextra America Intermediate Assembler or FabricatorHarris Salinas Rebar
Rebar Size8 Coupler Model8 Bartec Coupler
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop DiameterUnknown Rebar Hoop FabricatorUnknown
Coupler Component Heat/Lot Number(s)AM603732 Rebar Heat Number(s)SE17101192
Rebar Size 2 Not set
Test Details
DIME Sample ID: 2017-10-24-8
DIME Test ID: 2017-10-24-8-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Test Release Date: 2017-11-07
Test Results

Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 10/30/2017
UTM: 400KIP
Halo ID: Small
Temperature:72 F
NumSampleMfg. Lot Number(s)SizeArea (sqin)Slip (inch)Peak Load (lbf)Peak Stress (psi)CommentsTested By
121#8/25mm0.7907691997366OK NeckingFred

General comments (publicly viewable) (Max 1000 characters): OK Necking
Test Graph
Source: Partner Data Point File
Test graph for the Sample

Test was verified on 10/31/2017