Test 2017-10-16-6-3 (ASTM F606-14a) Summary

Project Information
Project IdentifiersProject ID: 210794
DEA: 062HT104
EFIS: 0612000287
DIST-CO-RTE-PM06-FRE-99-23.5/26.7
Work Description(Alternative Delivery) Realign Freeway CONTACT SMR PRIOR TO PERFORMING ANY TESTING OR INSPECTION. CMGC PROJECT. Realign Route 99 between Ashlan Avenue and Olive Avenue to accommodate the High Speed Train (HST).
Location DescriptionState Highway 99 in Fresno (Fresno County) from 0.2 miles North of Olive Ave over-crossing to 0.2 miles North of Ashlan Ave over-crossing.
Sample Information
Sample Taken Date10/16/2017 Sample Unique Key6
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/25/2017
Sample typeQuality Assurance A brief description of the samplean assortment of fastener assembles
The quantity of what the sample constitutes9 From where was the sample collectedManufacturer
First name of sampler or witnessed byPrakash Last name of sampler or witnessed byPatel
Title of samplerUnknown Laboratory sample identificationUnknown
The fabricator/manufacturer/facility nameAM Nut and Bolt Transportation Laboratory (TL) NumberUnknown
Inspector Lot Number from the Transportation Laboratory (TL) FormL11-056-17 Structure unique identifierNot set
Structure nameNot set
Material Information
Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)
Heat Number(s)58027325-05, 3070747, 58027948-03, 3072487, DL1610509701, 3068896, DL16106769, 166940, DL16105990, 161378, 158681, 170327, 171611 Nut Mfg. Lot Number(s)W3249, 386329A, W2027, 383997A
Washer Mfg. Lot Number(s)298040, 294692, 302919, 304143 Bolt SpecificationASTM F1554
Bolt Length(s)42", 18", 36", 13" Nut SpecificationASTM A194-2H
Washer SpecificationASTM A153 Class D, ASTM F2329 FinishHDG
Diameter/Size2", 3/4", 1" Bolt Mfg. Lot Number40140-PPO, 40023-PPO, 40121-PP0, 40118-PPO, 4
Rocap Test Requirement(s) Lubricant Requirements(s)
Test Details
DIME Sample ID: 2017-10-16-6
DIME Test ID: 2017-10-16-6-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2017-11-08
Test Results

Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 10/27/2017
UTM:400KIP
Temperature:72 F
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)CommentsTested By
17AL11056173/4\"59019262.53Nut Proof LoadFred

General comments (publicly viewable) (Max 1000 characters): Nut Proof Load
Test Graph
Source: Partner Data Point File

Test was verified on 11/01/2017