Summary for Test 2017-10-19-13-1

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 211673
DEA: 120M3504
EFIS: 1212000018
DIST-CO-RTE-PM12-ORA-405-2.6/6.5
Award Date11/29/2016
Closeout Date06/29/2020
Work DescriptionEXTD 2ND AUX LN ON SB 405, REPL EXIST K-RAIL TO TYPE 60/60C CONC BARR
Location DescriptionORANGE COUNTY IN IRVINE FROM 0.3 MILE SOUTH OF SAND CANYON AVENUE OVERCROSSING TO 0.4 MILE SOUTH OF JAMBOREE ROAD OVERCROSSING
QA Service Level1 (Verified on 02/24/2017)

Sample Information

Sample Taken Date10/19/2017 Sample Unique Key13
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/24/2017
Sample typeQuality Assurance A brief description of the sampleBarsplice Griptwist coupler
The quantity of what the sample constitutes4 From where was the sample collectedJob Site
First name of sampler or witnessed byKugan Last name of sampler or witnessed byRamanathan
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameBarsplice Transportation Laboratory (TL) NumberC385419
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingAuthorization Testing
Service or UltimateUltimate Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerGerdau
Coupler ManufacturerBarsplice Intermediate Assembler or FabricatorUnknown
Rebar Size8 Coupler ModelGrip Twist
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop DiameterUnknown Rebar Hoop FabricatorUnknown
Coupler Component Heat/Lot Number(s)177356, 177248 Rebar Heat Number(s)65026170
Rebar Size 2 Not set Coupler Unique IDNot set

Test Details

DIME Sample ID: 2017-10-19-13
DIME Test ID: 2017-10-19-13-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Test Release Date: 2017-11-03

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 10/27/2017
UTM: 400KIP
Halo ID: Small
Temperature: 72 F
NumSampleMfg. Lot Number(s)SizeArea (sqin)Slip (inch)Peak Load (lbf)Peak Stress (psi)CommentsTested By
111#8/25mm0.79-0.00227210791275OK NeckingFred

General comments (publicly viewable) (Max 1000 characters): OK Necking
Test Graph
Source: Partner Data Point File
Test graph for the Sample

Test was verified on 10/27/2017