Summary for Test 2017-10-19-3-3
Test performed: ASTM F606-14aProject Information
Project Identifiers | Project ID: 88888 DEA: SMTL-STOCK EFIS: SMTL-STOCK |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for SMTL stock material. Object Code: 1025. J2 DEA: 912680. |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 10/19/2017 | Sample Unique Key | 3 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/24/2017 |
Sample type | Stock | A brief description of the sample | Galvanized Heavy Hex Nuts |
The quantity of what the sample constitutes | 16200 Pieces | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Jeffrey | Last name of sampler or witnessed by | Sulka |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Blue Circle Corp | Transportation Laboratory (TL) Number | C970788 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L81-064-17 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | N/A |
---|---|---|---|
Heat Number(s) | 75065969 | Nut Mfg. Lot Number(s) | 26505-75065969 |
Washer Mfg. Lot Number(s) | NA | Bolt Specification | N/A |
Bolt Length(s) | NA | Nut Specification | ASTM A563 |
Washer Specification | N/A | Finish | Galvanized |
Diameter/Size | 5/8" | Bolt Mfg. Lot Number | NA |
Rocap Test Requirement(s) | NA | Lubricant Requirements(s) | Blue Dye |
Test Details
DIME Sample ID: 2017-10-19-3
DIME Test ID: 2017-10-19-3-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2017-11-06
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 10/26/2017
UTM: 400KIP
Temperature: 72 F
Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By |
---|---|---|---|---|---|---|---|
1 | 1C | 26505-75065969 | 5/8\" | 34525 | 153.57 | Nut Proof Load | Brian |
General comments (publicly viewable) (Max 1000 characters): Nut Proof Load
Test Graph
Source: Partner Data Point FileTest was verified on 10/30/2017 ✔