Summary for Test 2017-10-13-2-2
Test performed: ASTM F606-14aProject Information
Project Identifiers | Project ID: 3807 DEA: 07121844 EFIS: 0700000117 |
---|---|
DIST-CO-RTE-PM | 07-LA-5-42.8/47.3 |
Award Date | 12/06/2010 |
Closeout Date | 06/30/2021 |
Work Description | CONSTRUCT HOV LANES, RETAINING WALLS AND SOUND WALLS. |
Location Description | LOS ANGELES COUNTY IN LOS ANGELES, GLENDALE, AND BURBANK FROM ROUTE 5/134 SEPARATION TO MAGNOLIA BOULEVARD OVERCROSSING |
QA Service Level | 1 (Verified on 02/23/2012) |
Sample Information
Sample Taken Date | 10/13/2017 | Sample Unique Key | 2 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/17/2017 |
Sample type | Quality Assurance | A brief description of the sample | F1554 anchor Bolt |
The quantity of what the sample constitutes | 38 | From where was the sample collected | Distributor |
First name of sampler or witnessed by | Joe | Last name of sampler or witnessed by | Lanz |
Title of sampler | QA | Telephone number of sampler | 7072085241 |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Industrial Bolt and Supply | Transportation Laboratory (TL) Number | NA |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L10600217 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | NA |
---|---|---|---|
Heat Number(s) | NF14101170 | Nut Mfg. Lot Number(s) | 24875-166868 |
Washer Mfg. Lot Number(s) | 0514-489 | Bolt Specification | 105 |
Bolt Length(s) | 29 | Nut Specification | A563 |
Washer Specification | F436 | Finish | F2329 |
Diameter/Size | 1.5 | Bolt Mfg. Lot Number | |
Rocap Test Requirement(s) | NA | Lubricant Requirements(s) | Blue |
Test Details
DIME Sample ID: 2017-10-13-2
DIME Test ID: 2017-10-13-2-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2017-10-31
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 10/20/2017
UTM: 400KIP
Temperature: 72 F
Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By |
---|---|---|---|---|---|---|---|
1 | 1B | L10600217 | 1 1/2\" | 214320 | 953.35 | Proof Load | Fred |
General comments (publicly viewable) (Max 1000 characters): Proof Load
Test Graph
Source: Partner Data Point FileTest was verified on 10/24/2017 ✔