Test 2017-06-22-4-1 (CONCLP 3-16) Summary

Project Information
Project IdentifiersProject ID: 208682
DEA: 083401U4
EFIS: 0800000609
DIST-CO-RTE-PM08-SBD-138,138-6.2/6.4,2.3/R15.2
Work DescriptionWIDEN TO 4 LNS FR BEEKLEY RD TO JCT 15, ADD 1 LN EB FR PHELAN RD TO
Location DescriptionSAN BERNARDINO COUNTY ON ROUTE 138 NEAR PHELAN FROM 0.6 MILE WEST OF PHELAN ROAD TO THE JUNCTION OF ROUTE 15 AND ON ROUTE 2 FROM 0.1 MILE NORTH OF WILD HORSE CANYON ROAD TO ROUTE 138
Sample Information
Sample Taken Date6/22/2017 Sample Unique Key4
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing6/22/2017
Sample typeQuality Control A brief description of the sample1 gallon can
The quantity of what the sample constitutes2 tankers From where was the sample collectedSource
First name of sampler or witnessed byChris Last name of sampler or witnessed byNunes
Title of samplerUnknown Laboratory sample identificationUnknown
The fabricator/manufacturer/facility nameKwik bond and Reichhold Transportation Laboratory (TL) NumberSacramento Caltrans lab
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierNot set
Structure nameNot set
Material Information
Material TypePolyester Mfg. Lot Number(s)1057688
Batch number1057688 Mix number1057688
Test Details
DIME Sample ID: 2017-06-22-4
DIME Test ID: 2017-06-22-4-1
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: CONCLP 3-16: Polyester Resin
Test Release Date: 2017-10-06
Test Results

Input Type: Measured
Tester's full name: Mike Mullins
Date of test: 10/06/2017
Viscosity ASTM D 2196, RVT, No. 1 spindle 75 to 200 cps @ 20 RPM, 77°F: 95.5 cps
Specific gravity ASTM D 1475 1.05 to 1.10 @ 77°F: 1.06
Conditioning (18/25/50 + 5/70) Elogation ASTM D 638, minimum 35%: 54.5 %
Tensile Strength ASTM D 638 Type 1 @ 0.45 in/min, minimum 2500 psi: 2642 psi
Styrene ASTM D 2369 40% to 50 %: 46 %
PCC - SSD bond strength CTM 551 500 psi minimun @ 24 hours: 747 psi
Static Volatile Emissions, SCAQMD 309-91, maximum loss 1.0 grams: 0.5 grams
General comments (publicly viewable) (Max 1000 characters): Accepted QC results from supplier press down

Test was verified on 10/06/2017