Summary for Test 2013-12-03-8002992-2

Test performed: CTM 217-June 2011

Project Information

Project IdentifiersProject ID: 3995
DEA: 072332A4
EFIS: 0700000390
DIST-CO-RTE-PM07-LA-5-R46.3/R50.0
Award Date02/27/2012
Closeout Date06/02/2015
Work DescriptionWIDEN ROADWAY AND BRIDGES WITH PCC AND CONSTRUCT RETAINING WALLS.
Location DescriptionLOS ANGELES COUNTY IN AND NEAR SANTA CLARITA FROM 0.3 MILE SOUTH OF WELDON CANYON OVERCROSSING TO 0.4 MILE SOUTH OF PICO CANYON ROAD/LYONS AVENUE OVERCROSSING
QA Service Level1 (Verified on 04/23/2012)

Sample Information

Sample Taken Date12/03/2013 Sample Unique Key8002992
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing12/04/2013
Sample typeAcceptance A brief description of the sampleStructure Backfill Material
The quantity of what the sample constitutes1bag From where was the sample collectedSource
First name of sampler or witnessed byUnknown Last name of sampler or witnessed byUnknown
Title of samplerNot set Telephone number of samplerNot set
Laboratory sample identificationNot set Linked DIME Sample IDNot set
The fabricator/manufacturer/facility nameRW 2578 Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)RW 2578
The fabricator's/manufacturer's product name for the sampleNot set The fabricator/manufacturer designation for the sampleNot set
The plant numberNot set A detailed description of where the material sample was collectedRW 2578
Where the material sample would have been placed if not sampledNot set Primary Aggregate Nominal Size
The concrete mix design number Lot numberNot set
Sublot numberNot set Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2013-12-03-8002992
DIME Test ID: 2013-12-03-8002992-2
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 217-June 2011: Method of Test for Sand Equivalent
Test Release Date: 2015-02-20

Test Results


Number of tests: 1
Input Type: Calculated
Tester's full name: Vincent Onoh
Date of test: 12/29/2013
Temperature correction: no data
Temperature of solution: no data
Clay reading (test 1): no data
Sand reading (test 1): no data
Sand equivalent (test 1): no data
Sand equivalent before temperature correction: no data
Sand equivalent after temperature correction: 26
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 2/20/2015