Summary for Test 2017-09-06-2-4

Test performed: ASTM F606-14a

Project Information

Project IdentifiersProject ID: 211513
DEA: 120M4904
EFIS: 1212000090
DIST-CO-RTE-PM12-ORA-5-1.2/2.2
Award Date09/20/2016
Closeout Date01/09/2020
Work DescriptionWIDEN FWY AND BRIDGE AND CONSTRUCT RW, SOUND WALL, AND CONC BARRIERS.
Location DescriptionORANGE COUNTY IN SAN CLEMENTE FROM 0.1 MILE NORTH OF AVENIDA MENDOCINO OVERCROSSING TO 0.2 MILE SOUTH OF AVENIDA PRESIDIO UNDERCROSSING
QA Service Level1 (Verified on 11/03/2016)

Sample Information

Sample Taken Date09/06/2017 Sample Unique Key2
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing09/12/2017
Sample typeQuality Assurance A brief description of the sampleA 325 bolt
The quantity of what the sample constitutes7 lots From where was the sample collectedFabricator
First name of sampler or witnessed byGreg Last name of sampler or witnessed byJohnston
Title of sampler Telephone number of sampler9165247768
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameStinger Bridge Iron Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)TT008087, TT0087088, TT0087089, TT0087090, TT0087091, TT0087092, TT0087190, TT0087191, TT0087192, TT0087193, TT0087194, TT0087195
Heat Number(s) Nut Mfg. Lot Number(s)23286-6214073905
Washer Mfg. Lot Number(s)0416-213, 1116-407 Bolt SpecificationA325
Bolt Length(s)3/4 x 2, 3/4 x 2 1/4, 7/8 x 2, 7/8 x 2 1/4, 7 Nut SpecificationA563
Washer SpecificationF436 FinishMG
Diameter/Size Bolt Mfg. Lot Number
Rocap Test Requirement(s)Yes Lubricant Requirements(s)Yes

Test Details

DIME Sample ID: 2017-09-06-2
DIME Test ID: 2017-09-06-2-4
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2017-09-22

Test Results


Number of Bolt Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 09/14/2017
UTM: 400KIP
Temperature: no data
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)Wedge Angle (deg)CommentsTested By
19ANA7/8\"65101289.610A325Brian

General comments (publicly viewable) (Max 1000 characters): A325
Test Graph
Source: Partner Data Point File

Test was verified on 9/15/2017