Summary for Test 2017-09-11-2-3
Test performed: CTM 670-December 2013Project Information
Project Identifiers | Project ID: 211716 DEA: 101C4214 EFIS: 1015000131 |
---|---|
DIST-CO-RTE-PM | 10-SJ-99-14.3/14.9,18.4/23.0 |
Award Date | 12/28/2016 |
Closeout Date | 10/09/2018 |
Work Description | RAMP WIDENING, INSTALL RAMP METERING AND FIBER OPTIC CABLE. |
Location Description | SAN JOAQUIN COUNTY IN STOCKTON FROM 0.3 MILE SOUTH TO 0.3 MILE NORTH OF ARCH ROAD UNDERCROSSING AND FROM 0.3 MILE NORTH OF MAIN STREET OVERCROSSING TO 0.1 MILE NORTH OF HAMMER LANE OVERCROSSING |
QA Service Level | 1 (Verified on 10/20/2016) |
Sample Information
Sample Taken Date | 09/11/2017 | Sample Unique Key | 2 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/12/2017 |
Sample type | Quality Assurance | A brief description of the sample | 4 Flash Welded hoops |
The quantity of what the sample constitutes | 4 | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Ed | Last name of sampler or witnessed by | Fleming |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Harris Rebar | Transportation Laboratory (TL) Number | C741515 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | B1028517 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM5 - Welded Hoops | Production or Authorization Testing | Production Testing |
---|---|---|---|
Service or Ultimate | Ultimate | Rebar Heat Number(s) | SE13106226 |
Hoop Manufacturer Lot Number(s) | H01 | Material Standard Code | ASTM A706 |
Material Grade | 60 | Rebar Size | 4 |
Diameter of Hoop | 2'-2" | Epoxy Coated | No |
Epoxy Coating Color | NA | Rebar Manufacturer | Nucor |
Welding Company | Harris Rebar | Coating Standards | Uncoated |
Weld Type | Flash Welded |
Test Details
DIME Sample ID: 2017-09-11-2
DIME Test ID: 2017-09-11-2-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2017-09-20
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 09/12/2017
UTM: 75KIP
Temperature: 72 F
Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|
1 | 3 | H01 | #4/13mm | 0.2 | 19639 | 98190 | necking okay | Fred |
General comments (publicly viewable) (Max 1000 characters): necking okay
Test Graph
Source: Partner Data Point FileTest graph for the Sample
Test was verified on 9/13/2017 ✔