Test 2017-08-28-3-2 (ASTM E23-12c) Summary

Project Information
Project IdentifiersProject ID: 212557
DEA: 033H3604
EFIS: 0317000330
DIST-CO-RTE-PM03-ED-89-16.0/16.8
Work DescriptionInstall soldier pile wall, barrier slab and barrier rail
Location DescriptionNot set
Sample Information
Sample Taken Date8/28/2017 Sample Unique Key3
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing8/28/2017
Sample typeVerification A brief description of the sampleRailroad Rail
The quantity of what the sample constitutes2 From where was the sample collectedSource
First name of sampler or witnessed byMike Last name of sampler or witnessed byMorgan
Title of samplerUnknown Laboratory sample identificationUnknown
The fabricator/manufacturer/facility nameSteel Dynamics Transportation Laboratory (TL) NumberC740527
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierNot set
Structure nameNot set
Material Information
Material TypeSMTL TM6 - Steel Check Sample Plate Heat Number(s)Various
Material SpecificationA709 GradeAREMA SS
ThicknessVarious ShapeRailroad Rail
Metal Foundry Manufacturer (Mill)Steel Dynamics Plate Dimension115RE
Test Details
DIME Sample ID: 2017-08-28-3
DIME Test ID: 2017-08-28-3-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM E23-12c: Standard Test Methods for Notched Bar Impact Testing of Metallic Materials (Charpy Impact)
Test Release Date: 2017-09-12
Test Results

Input Type: Measured
Tester's full name: Glen Weldon
Date of test: 08/28/2017
Temperature Required: 40 oF
Minimum Energy Required: 0 ftlb
Test Temperature 1: 39 oF
Impact Energy 1: 5 ftlb
Impact Energy 2: 4 ftlb
Impact Energy 3: 5 ftlb
Striker Radius: 8 mm
Average Impact Energy:5 ftlb
Value Exceeds The Machine Capacity?:No
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 09/05/2017