Test 2013-10-29-10007272-1 (CTM 202-November 2011) Summary

Project Information
Project IdentifiersProject ID: 3958
DEA: 07215914
EFIS: 0700001831
DIST-CO-RTE-PM07-LA-5-1.2/2.1
Work DescriptionWIDEN AND REALIGN FREEWAY AND RECONSTRUCT OVERCROSSING STRUCTURE.
Location DescriptionLOS ANGELES COUNTY IN SANTA FE SPRINGS FROM 0.3 MILE SOUTH OF NORTH FORK COYOTE CREEK BRIDGE TO 0.3 MILE NORTH OF MARQUARDT AVENUE AND AT NORWALK HUB AND LOS ANGELES REGIONAL TRANSPORTATION MANAGEMENT CENTER
Sample Information
Sample Taken Date10/29/2013 Sample Unique Key10007272
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing11/20/2013
Sample typeAnnual Source Testing A brief description of the sample1-1/2 PCC Aggregates
The quantity of what the sample constitutes5 Bags From where was the sample collectedSource
First name of sampler or witnessed byUnknown Last name of sampler or witnessed byUnknown
Title of samplerNot set Laboratory sample identification3294B
The fabricator/manufacturer/facility nameRobertsons - Cabazon Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifierNot set
Structure nameNot set
Material Information
Material TypeAggregate Source Identification (SMARA or name of Pit)SMARA 91-33-0008
The fabricator's/manufacturer's product name for the sampleNot set The fabricator/manufacturer designation for the sampleNot set
The plant numberNot set A detailed description of where the material sample was collectedStockpiles
Where the material sample would have been placed if not sampledNot set Primary Aggregate Nominal Size1-1/2 inch
The concrete mix design number Lot numberNot set
Sublot numberNot set HMA Design ID
Test Details
DIME Sample ID: 2013-10-29-10007272
DIME Test ID: 2013-10-29-10007272-1
Testing Lab: CT - Southern Regional Laboratory
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2014-04-07
Test Results

What size aggregate is being tested?: 1.5 in. x 0.75 in. - Coarse Aggregate
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Input Type: Calculated
Tester's full name: Charles McDonald
Date of test: 12/04/2013
Cumulative percent passing the 2 in. sieve:100 %
Cumulative percent passing the 1 1/2 in. sieve:98 %
Cumulative percent passing the 1 in. sieve:42 %
Cumulative percent passing the 3/4 in. sieve:4 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 04/07/2014