Summary for Test 2017-08-25-1-1

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 211556
DEA: 11237964
EFIS: 1114000046
DIST-CO-RTE-PM11-SD-8-5.4/10.6,R20.0/R21.6
Award Date09/26/2016
Closeout Date08/16/2021
Work DescriptionINSTALL CCTV CAMERAS, CMS, LDS, VDS, F/O CABLE, TMS, RHMA, AND SIGNS.
Location DescriptionSAN DIEGO COUNTY IN SAN DIEGO, LA MESA, AND NEAR EL CAJON FROM 0.2 MILE WEST OF ROUTE 15/8 SEPARATION TO FLETCHER PARKWAY OVERCROSSING AND FROM LOS COCHES ROAD UNDERCROSSING TO 0.2 MILE WEST OF LAKE JENNINGS PARK ROAD UNDERCROSSING
QA Service Level1 (Verified on 11/15/2016)

Sample Information

Sample Taken Date08/25/2017 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/30/2017
Sample typeQuality Assurance A brief description of the sample Resistance Butt Welded Hoops
The quantity of what the sample constitutes4 From where was the sample collectedFabricator
First name of sampler or witnessed byRussell Last name of sampler or witnessed byLynch
Title of samplerQAI Telephone number of sampler(213) 538-8219
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameTNT Rebar Transportation Laboratory (TL) NumberC939707
Inspector Lot Number from the Transportation Laboratory (TL) FormL96-140-17 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateUltimate Rebar Heat Number(s)393016
Hoop Manufacturer Lot Number(s)1 Material Standard CodeASTM A706
Material Grade60 Rebar Size4
Diameter of Hoop2'-2" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerCascade
Welding CompanyTNT Rebar Coating StandardsUncoated
Weld TypeFlash Welded

Test Details

DIME Sample ID: 2017-08-25-1
DIME Test ID: 2017-08-25-1-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2017-09-06

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 08/30/2017
UTM: 75KIP
Temperature: 72 F
NumSampleMfg. Lot Number(s)SizeArea (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
111#4/13mm0.21889194460necking okayFred

General comments (publicly viewable) (Max 1000 characters): necking okay
Test Graph
Source: Partner Data Point File
Test graph for the Sample

Test was verified on 8/30/2017