Summary for Test 2017-08-23-2-1

Test performed: ASTM F606-14a

Project Information

Project IdentifiersProject ID: 211393
DEA: 081F1104
EFIS: 0814000160
DIST-CO-RTE-PM08-SBD-38-38.6-L5759
Award Date06/30/2016
Closeout Date12/02/2019
Work DescriptionCONSTRUCT A SAND HOUSE AND CHAIN LINK FENCE AT ONYX SUMMIT
Location DescriptionSAN BERNARDINO COUNTY AT ONYX SUMMIT 0.7 MILES SOUTH OF PIPES ROAD
QA Service Level1 (Verified on 07/18/2016)

Sample Information

Sample Taken Date08/23/2017 Sample Unique Key2
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/28/2017
Sample typeQuality Assurance A brief description of the sampleA325 Fastener Assembly
The quantity of what the sample constitutesLot 2 From where was the sample collectedJob Site
First name of sampler or witnessed byDavid Last name of sampler or witnessed byWeeks
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameJobsite Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormL79-034-17 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)2
Heat Number(s)Bolt-NF16103170, Nut-DL16101605, Washer-262347 Nut Mfg. Lot Number(s)375883B
Washer Mfg. Lot Number(s)0317-495 Bolt SpecificationA325
Bolt Length(s)3 Nut SpecificationA563
Washer SpecificationF436 FinishHDG
Diameter/Size1 Bolt Mfg. Lot Number382895A
Rocap Test Requirement(s) Lubricant Requirements(s)

Test Details

DIME Sample ID: 2017-08-23-2
DIME Test ID: 2017-08-23-2-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2017-09-13

Test Results


Number of Bolt Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 08/30/2017
UTM: 400KIP
Temperature: no data
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)Wedge Angle (deg)CommentsTested By
13AL79-034-171\"85395379.910A325Brian

General comments (publicly viewable) (Max 1000 characters): A325
Test Graph
Source: Partner Data Point File

Test was verified on 9/6/2017