Summary for Test 2017-08-08-11-3
Test performed: CTM 670-December 2013Project Information
Project Identifiers | Project ID: 211668 DEA: 010B2604 EFIS: 0112000150 |
---|---|
DIST-CO-RTE-PM | 01-DN-199-8.2 |
Award Date | 11/07/2016 |
Closeout Date | 01/07/2019 |
Work Description | CONSTRUCT BRIDGE AND WIDEN SHOULDERS |
Location Description | DEL NORTE COUNTY NEAR HIOUCHI AT 1 MILE NORTH OF SOUTH FORK ROAD |
QA Service Level | 1 (Verified on 09/27/2016) |
Sample Information
Sample Taken Date | 08/08/2017 | Sample Unique Key | 11 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/28/2017 |
Sample type | Quality Assurance | A brief description of the sample | Barsplice Griptwist coupler |
The quantity of what the sample constitutes | 8 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | J | Last name of sampler or witnessed by | CERVANTES |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Barsplice, CMC rebar | Transportation Laboratory (TL) Number | C944551 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | NA | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM5 - Couplers | Production or Authorization Testing | Production Testing |
---|---|---|---|
Service or Ultimate | Ultimate | Material Standard Code | ASTM A706 |
Material Grade | 60 | Rebar Manufacturer | CMC Rebar |
Coupler Manufacturer | BarSplice | Intermediate Assembler or Fabricator | Unknown |
Rebar Size | #7, 10 | Coupler Model | Taper GripTwist |
Coating Standards | Uncoated | Shape of Rebar | Straight |
Rebar Hoop Diameter | Unknown | Rebar Hoop Fabricator | Unknown |
Coupler Component Heat/Lot Number(s) | A152001,144107,133548, 177248, | Rebar Heat Number(s) | 4063522, 4061543 |
Rebar Size 2 | Not set | Coupler Unique ID | Not set |
Test Details
DIME Sample ID: 2017-08-08-11
DIME Test ID: 2017-08-08-11-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Test Release Date: 2017-09-05
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 08/29/2017
UTM: 2000KIP
Halo ID: Big
Temperature: 72 F
Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Slip (inch) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|---|
1 | 3 | 1 | #10/32mm | 1.27 | 0 | 121068 | 95329 | necking okay | Fred |
General comments (publicly viewable) (Max 1000 characters): necking okay
Test Graph
Source: Partner Data Point FileTest graph for the Sample
Test was verified on 8/29/2017 ✔