Summary for Test 2017-08-24-5-5

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 212357
DEA: 044K0904
EFIS: 0417000164
Permit Numbers: 0417NOP0443 04176DP0541 0417NRD0562 0415NMC2719
DIST-CO-RTE-PM04-SM-84-25.8/26.5
Award Date03/08/2017
Closeout Date08/22/2018
Work DescriptionImprove the intersection of Bayfront Expressway at Chrysler Drive by widening to accommodate additional left turn-lanes and bike lanes; and install signing, striping, curb ramps, and sidewalk per approved Project 0417000256 (EA No. 4K0904), on State Highway 04-SM-84, Post Miles 25.8/26.5, in the Ci
Location DescriptionBayfront Expressway, Menlo Park
QA Service Level1 (Verified on 05/05/2017)

Sample Information

Sample Taken Date08/24/2017 Sample Unique Key5
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/25/2017
Sample typeQuality Assurance A brief description of the sampleFlash Welded hoops
The quantity of what the sample constitutes4 QA samples for each heat number From where was the sample collectedFabricator
First name of sampler or witnessed byJames Last name of sampler or witnessed byDoe
Title of samplerQA Inspector Telephone number of sampler510-918-4918
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameMission City Rebar Transportation Laboratory (TL) NumberUnknown
Inspector Lot Number from the Transportation Laboratory (TL) FormB358-054-17 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingAuthorization Testing
Service or UltimateUltimate Rebar Heat Number(s)SE16104823, 158717
Hoop Manufacturer Lot Number(s)1 Material Standard CodeASTM A706
Material Grade60 Rebar Size5
Diameter of Hoop38", 32" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerNucore Cascade
Welding CompanyMission City Rebar Coating StandardsUncoated
Weld TypeFlash Welded

Test Details

DIME Sample ID: 2017-08-24-5
DIME Test ID: 2017-08-24-5-5
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2017-09-04

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 08/25/2017
UTM: 75KIP
Temperature: 72 F
NumSampleMfg. Lot Number(s)SizeArea (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
121#5/16mm0.313073999160necking okayFred

General comments (publicly viewable) (Max 1000 characters): necking okay
Test Graph
Source: Partner Data Point File
Test graph for the Sample

Test was verified on 8/28/2017