Summary for Test 2017-08-16-3-1

Test performed: ASTM A370-15

Project Information

Project IdentifiersProject ID: 210618
DEA: 06342534
EFIS: 0600000382
COOP: 061616A2
DIST-CO-RTE-PM06-FRE-180-R74.1/R78.6
Award Date04/05/2017
Closeout Date07/06/2021
Work DescriptionCONSTRUCT SEGMENT 3 OF KINGS CANYON EXPRESSWAY
Location DescriptionFRESNO COUNTY ABOUT 8.4 MILES EAST OF FRESNO FROM 0.7 MILE WEST OF SMITH AVENUE TO 0.7 MILE EAST OF FRANKWOOD AVENUE
QA Service Level1 (Verified on 07/10/2017)

Sample Information

Sample Taken Date08/16/2017 Sample Unique Key3
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/21/2017
Sample typeQuality Assurance A brief description of the sample2 Ductile Iron Casting
The quantity of what the sample constitutes2 From where was the sample collectedManufacturer
First name of sampler or witnessed byDebbie Last name of sampler or witnessed byOzuna
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameDywidag Systems Transportation Laboratory (TL) NumberUnknown
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM6 - Ductile Iron Cast Samples Heat Number (s)2087
Part Number (s)68 31 216 246 Material SpecificationA536
Grades65-45-12 Metal Foundry Manufacturer (Mill)Golden Foundary Machine Co
Prestressing ManufacturerDywidag Systems

Test Details

DIME Sample ID: 2017-08-16-3
DIME Test ID: 2017-08-16-3-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Test Release Date: 2017-08-29

Test Results


Number of Samples: 2
Input Type: Calculated
Tester's full name: Fred
Date of test: 08/22/2017
UTM: 67KIP
Temperature: 72 F
NumSampleHeat NumberDiameter (in)Area (sqin)Stress at Offset (psi)Tensile Strength (psi)Elongation in 4 x d (%)Tested By
120670.4970.194447977236020Fred
220670.4970.194445977200020.2Fred

General comments (publicly viewable) (Max 1000 characters):
Test Graph

Test was verified on 8/22/2017