Summary for Test 2017-07-27-16-1

Test performed: AGGLP SIEVE_ANALYSIS-1

Project Information

Project IdentifiersProject ID: 212622
DEA: 051F0804
EFIS: 0513000052
DIST-CO-RTE-PM05-MON-1-2.5-67.3
Award Date10/02/2018
Closeout Date08/23/2021
Work DescriptionREPLACEMENT OF 7 CULVERTS ALONG HWY 1.
Location DescriptionON ROUTE 1 IN MONTEREY COUNTY AT VARIOUS LOCATIONS BETWEEN 2.5 MILES NORTH OF THE MONTEREY/SAN LUIS OBISPO COUNTY LINE AND 0.6 MILES SOUTH OF MALPASO CREEK BRIDGE.
QA Service Level1 (Verified on 09/30/2019)

Sample Information

Sample Taken Date07/27/2017 Sample Unique Key16
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/09/2017
Sample typeQuality Control A brief description of the sampleCulvert replacement @ Loc 7 PM 67.3
The quantity of what the sample constitutes1 bag From where was the sample collectedJob Site
First name of sampler or witnessed byRyan Last name of sampler or witnessed byDuran
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identification17SOIL-0244 Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameNA Transportation Laboratory (TL) NumberC835960
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSoil The fabricator's/manufacturer's product name for the sampleUnknown
The fabricator/manufacturer designation for the sampleUnknown A detailed description of where the material sample was collectedRW-17-005
Where the material sample would have been placed if not sampled0 to 5 ft

Test Details

DIME Sample ID: 2017-07-27-16
DIME Test ID: 2017-07-27-16-1
Testing Lab: CT HQ - Sacramento Aggregate Testing Laboratory
Test Method: AGGLP SIEVE_ANALYSIS-1: Soils for Corrosion Sieve Analysis
Test Release Date: 2017-08-18

Test Results


Input Type: Measured
Tester's full name: Phillip Montes
Date of test: 08/18/2017
Total mass of material in the sample: 20314 grams
Cumulative mass retained on the 2 in. sieve: 0 grams
Cumulative mass retained on the 1 1/2 in. sieve: 0 grams
Cumulative mass retained on the 1 in. sieve: 32 grams
Cumulative mass retained on the 3/4 in. sieve: 13 grams
Cumulative mass retained on the 1/2 in. sieve: 29 grams
Cumulative mass retained on the 3/8 in. sieve: 7 grams
Cumulative mass retained on the #4 sieve: 46 grams
Cumulative mass retained on the #8 sieve: 49 grams
Total sample mass passing the #4 sieve: 2450 grams
Total mass of fine material in the sample: 605 grams
Cumulative mass retained on the pan: 554 grams
Total cumulative mass of coarse aggregate: 127 grams
Total cumulative mass of fine aggregate: 603 grams
Sum of coarse and fine aggregate: 2577 grams
Percentage of coarse material: 5 %
Percentage of fine material: 95 %
Cumulative percent passing the 2 in. sieve: 100 %
Cumulative percent passing the 1 1/2 in. sieve: 100 %
Cumulative percent passing the 1 in. sieve: 99 %
Cumulative percent passing the 3/4 in. sieve: 98 %
Cumulative percent passing the 1/2 in. sieve: 97 %
Cumulative percent passing the 3/8 in. sieve: 97 %
Cumulative percent passing the #4 sieve: 95 %
Cumulative percent passing the #8 sieve: 87 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 8/18/2017