Summary for Test 2017-07-27-11-1
Test performed: ASTM C39-17aProject Information
Project Identifiers | Project ID: 211671 DEA: 07281504 EFIS: 0700000552 |
---|---|
DIST-CO-RTE-PM | 07-LA,VEN-101-29.3/38.2,0.0/1.2 |
Award Date | 12/09/2016 |
Closeout Date | 05/04/2020 |
Work Description | CONSTRUCT STORM WATER TREATMENT SYSTEMS. |
Location Description | LOS ANGELES AND VENTURA COUNTIES AT VARIOUS LOCATIONS |
QA Service Level | 1 (Verified on 01/23/2017) |
Sample Information
Sample Taken Date | 07/27/2017 | Sample Unique Key | 11 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/03/2017 |
Sample type | Quality Control | A brief description of the sample | 6x12 |
The quantity of what the sample constitutes | 2 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | a | Last name of sampler or witnessed by | maghsoudlou |
Title of sampler | asr | Telephone number of sampler | Unknown |
Laboratory sample identification | 960-58 | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | np | Transportation Laboratory (TL) Number | 193658 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | location 28 austin vault |
Structure name | Unknown |
Material Information
Material Type | Concrete | The concrete mix design number | np |
---|---|---|---|
The truck number from where the sample was collected | Unknown | The batch plant ticket number from where the sample was collected | np |
Concrete batch plant | Unknown | The fabricator/manufacturer designation for the sample | Unknown |
A detailed description of where the material sample was collected | load 2 | Where the material sample would have been placed if not sampled | Unknown |
From Lot No. | Unknown | Bag Lot No. | Unknown |
Test Details
DIME Sample ID: 2017-07-27-11
DIME Test ID: 2017-07-27-11-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2017-08-17
Test Results
Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: Matthew Clayton
Date of test: 08/17/2017
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 6.00 in
Average diameter of cylinder 2: 6.02 in
Maximum load on cylinder 1: 107260 lb
Maximum load on cylinder 2: 104770 lb
Type of fracture pattern of cylinder 1: 1
Type of fracture pattern of cylinder 2: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: no data
Age of specimen: 21 days
Age of specimen in hours: no data
Cross sectional area of cylinder 1: 28.27 in^2
Cross sectional area of cylinder 2: 28.46 in^2
Compressive strength of cylinder 1: 3794.1 psi
Compressive strength of cylinder 2: 3681.3 psi
Compressive strength (to nearest 10 psi): 3740 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 8/17/2017 ✔