Test 2017-08-15-4-7 (CTM 670-December 2013) Summary

Project Information
Project IdentifiersProject ID: 211616
DEA: 050G0404
EFIS: 0500020020
DIST-CO-RTE-PM05-SLO,MON-101-63.2/R69.3,R0.0/R1.9
Work DescriptionROADWAY REHABILITATION AND BRIDGE CONSTRUCTION.
Location DescriptionSAN LUIS OBISPO AND MONTERY COUNTIES NEAR PASO ROBLES FROM 0.5 MILE SOUTH OF SAN MARCOS CREEK BRIDGE TO 0.2 MILE SOUTH OF BRADLEY ROAD OVERCROSSING
Sample Information
Sample Taken Date8/15/2017 Sample Unique Key4
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing8/16/2017
Sample typeRecertification A brief description of the sampleAnnual Machine Qualification
The quantity of what the sample constitutes10 hoops From where was the sample collectedFabricator
First name of sampler or witnessed byKevin Last name of sampler or witnessed byChurchill
Title of samplerQA Inspector Laboratory sample identificationUnknown
The fabricator/manufacturer/facility nameTNT Rebar Transportation Laboratory (TL) NumberUnknown
Inspector Lot Number from the Transportation Laboratory (TL) FormL02-059-17 Structure unique identifierNot set
Structure nameNot set
Material Information
Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingAuthorization Testing
Service or UltimateUltimate Rebar Heat Number(s)6502682202
Hoop Manufacturer Lot Number(s)1R Material Standard CodeASTM A706
Material Grade60 Rebar Size7
Diameter of Hoop2'-0" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerGerdau
Welding CompanyTNT Rebar Coating StandardsUncoated
Weld TypeFlash Welded
Test Details
DIME Sample ID: 2017-08-15-4
DIME Test ID: 2017-08-15-4-7
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical)
Test Release Date: 2017-09-14
Test Results

Number of Samples Tested: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 08/17/2017
UTM:400KIP
Temperature:72 F
NumSampleNumber of CyclesSizeMfg. Lot Number(s)Area (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
1Break-7100#7/22mmMach #H5746R0.661177101962NECKING OKFred

General comments (publicly viewable) (Max 1000 characters): NECKING OK
Test Graph
Source: Partner Data Point File

Test was verified on 09/07/2017