Summary for Test 2017-08-04-4-1
Test performed: ASTM A370-15Project Information
Project Identifiers | Project ID: 210618 DEA: 06342534 EFIS: 0600000382 COOP: 061616A2 |
---|---|
DIST-CO-RTE-PM | 06-FRE-180-R74.1/R78.6 |
Award Date | 04/05/2017 |
Closeout Date | 07/06/2021 |
Work Description | CONSTRUCT SEGMENT 3 OF KINGS CANYON EXPRESSWAY |
Location Description | FRESNO COUNTY ABOUT 8.4 MILES EAST OF FRESNO FROM 0.7 MILE WEST OF SMITH AVENUE TO 0.7 MILE EAST OF FRANKWOOD AVENUE |
QA Service Level | 1 (Verified on 07/10/2017) |
Sample Information
Sample Taken Date | 08/04/2017 | Sample Unique Key | 4 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/11/2017 |
Sample type | Quality Assurance | A brief description of the sample | Ductile Iron Casting |
The quantity of what the sample constitutes | 1 | From where was the sample collected | Source |
First name of sampler or witnessed by | Debbie | Last name of sampler or witnessed by | Ozuna |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | DSI | Transportation Laboratory (TL) Number | Unknown |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM6 - Ductile Iron Cast Samples | Heat Number (s) | 13G17 |
---|---|---|---|
Part Number (s) | 6812246 216 | Material Specification | A536 |
Grades | 65-45-12 | Metal Foundry Manufacturer (Mill) | Manchester Metals |
Prestressing Manufacturer | DSI |
Test Details
DIME Sample ID: 2017-08-04-4
DIME Test ID: 2017-08-04-4-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Test Release Date: 2017-08-22
Test Results
Number of Samples: 1
Input Type: Calculated
Tester's full name: Fred
Date of test: 08/15/2017
UTM: 67KIP
Temperature: 72 F
Num | Sample | Heat Number | Diameter (in) | Area (sqin) | Stress at Offset (psi) | Tensile Strength (psi) | Elongation in 4 x d (%) | Tested By |
---|---|---|---|---|---|---|---|---|
1 | 13G17 | 0.494 | 0.1917 | 48499 | 78640 | 13.3 | Fred |
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Test was verified on 8/15/2017 ✔