Summary for Test 2017-07-28-2-3
Test performed: ASTM F606-14aProject Information
Project Identifiers | Project ID: 88888 DEA: SMTL-STOCK EFIS: SMTL-STOCK |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for SMTL stock material. Object Code: 1025. J2 DEA: 912680. |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 07/28/2017 | Sample Unique Key | 2 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/08/2017 |
Sample type | Quality Assurance | A brief description of the sample | F1554 Grade 55 HDG Anchor Bolts |
The quantity of what the sample constitutes | 307 | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | William | Last name of sampler or witnessed by | Clifford |
Title of sampler | QA Inspector | Telephone number of sampler | (510) 325-3065 |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | AM Nut and Bolt | Transportation Laboratory (TL) Number | Unknown |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L78-036-17 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | N/A |
---|---|---|---|
Heat Number(s) | 3070747 | Nut Mfg. Lot Number(s) | 367505A |
Washer Mfg. Lot Number(s) | 294692 | Bolt Specification | A529 Gr55, F1554 |
Bolt Length(s) | 30" | Nut Specification | A194 |
Washer Specification | F436 | Finish | HDG |
Diameter/Size | 3/4" | Bolt Mfg. Lot Number | 3070747 |
Rocap Test Requirement(s) | Lubricant Requirements(s) |
Test Details
DIME Sample ID: 2017-07-28-2
DIME Test ID: 2017-07-28-2-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2017-08-21
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 08/10/2017
UTM: 400KIP
Temperature: 72 F
Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By |
---|---|---|---|---|---|---|---|
1 | 1B | L78-036-17 | 3/4\" | 58957 | 262.25 | Nut Proof | Brian |
General comments (publicly viewable) (Max 1000 characters): Nut Proof
Test Graph
Source: Partner Data Point FileTest was verified on 8/14/2017 ✔