Summary for Test 2017-07-10-7-1
Test performed: AGGLP SIEVE_ANALYSIS-1Project Information
Project Identifiers | Project ID: 212596 DEA: 100L0204 EFIS: 1013000053 |
---|---|
DIST-CO-RTE-PM | 10-SJ,STA-99-0.0-0.7:24.4-24.8 |
Award Date | 11/30/2018 |
Closeout Date | 07/15/2021 |
Work Description | Partial Bridge Replacement |
Location Description | ON ROUTE 99 IN RIPON AT THE COUNTY LINE OF SAN JOAQUIN COUNTY AND STANISLAUS COUNTY AT THE STANISLAUS RIVER BRIDGES (29-0013L/R). |
QA Service Level | 1 (Verified on 12/19/2018) |
Sample Information
Sample Taken Date | 07/10/2017 | Sample Unique Key | 7 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/28/2017 |
Sample type | Quality Control | A brief description of the sample | Stanislaus River Bridge |
The quantity of what the sample constitutes | 1 bag | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Fernando | Last name of sampler or witnessed by | De Haro |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | 17SOIL-0239 | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | NA | Transportation Laboratory (TL) Number | C637025 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | Soil | The fabricator's/manufacturer's product name for the sample | Unknown |
---|---|---|---|
The fabricator/manufacturer designation for the sample | Unknown | A detailed description of where the material sample was collected | RC-17-001 |
Where the material sample would have been placed if not sampled | 55 to 100 ft |
Test Details
DIME Sample ID: 2017-07-10-7
DIME Test ID: 2017-07-10-7-1
Testing Lab: CT HQ - Sacramento Aggregate Testing Laboratory
Test Method: AGGLP SIEVE_ANALYSIS-1: Soils for Corrosion Sieve Analysis
Test Release Date: 2017-08-09
Test Results
Input Type: Measured
Tester's full name: Phillip Montes
Date of test: 08/09/2017
Total mass of material in the sample: 2475 grams
Cumulative mass retained on the 2 in. sieve: 0 grams
Cumulative mass retained on the 1 1/2 in. sieve: 0 grams
Cumulative mass retained on the 1 in. sieve: 0 grams
Cumulative mass retained on the 3/4 in. sieve: 0 grams
Cumulative mass retained on the 1/2 in. sieve: 0 grams
Cumulative mass retained on the 3/8 in. sieve: 3 grams
Cumulative mass retained on the #4 sieve: 3 grams
Cumulative mass retained on the #8 sieve: 3 grams
Total sample mass passing the #4 sieve: 1207 grams
Total mass of fine material in the sample: 453 grams
Cumulative mass retained on the pan: 451 grams
Total cumulative mass of coarse aggregate: 6 grams
Total cumulative mass of fine aggregate: 454 grams
Sum of coarse and fine aggregate: 1213 grams
Percentage of coarse material: 0 %
Percentage of fine material: 100 %
Cumulative percent passing the 2 in. sieve: 100 %
Cumulative percent passing the 1 1/2 in. sieve: 100 %
Cumulative percent passing the 1 in. sieve: 100 %
Cumulative percent passing the 3/4 in. sieve: 100 %
Cumulative percent passing the 1/2 in. sieve: 100 %
Cumulative percent passing the 3/8 in. sieve: 100 %
Cumulative percent passing the #4 sieve: 100 %
Cumulative percent passing the #8 sieve: 99 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 8/9/2017 ✔