Summary for Test 2017-08-04-1-4

Test performed: ASTM A722-15

Project Information

Project IdentifiersProject ID: 211669
DEA: 022C0904
EFIS: 0200000161
DIST-CO-RTE-PM02-PLU-70-50.6/51.7
Award Date11/16/2016
Closeout Date11/12/2020
Work DescriptionBRIDGE WIDENING AND DECK REPLACEMENT, HMA, MGS AND CULVERT REPLACEMENT
Location DescriptionPLUMAS COUNTY NEAR QUINCY FROM 0.6 MILE WEST TO 0.5 MILE EAST OF SPRING GARDEN BRIDGE OVERHEAD
QA Service Level1 (Verified on 10/25/2016)

Sample Information

Sample Taken Date08/04/2017 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/08/2017
Sample typeQuality Assurance A brief description of the sample1 inch all-thread bar
The quantity of what the sample constitutes101 of 4 foot bars From where was the sample collectedFabricator
First name of sampler or witnessed byRussell Last name of sampler or witnessed byLynch
Title of samplerQAI Telephone number of sampler(213) 538-8219
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameWilliams Form Eng Transportation Laboratory (TL) NumberC939701
Inspector Lot Number from the Transportation Laboratory (TL) FormL96-126-17 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Threaded Bar Production or Authorization TestingAuthorization Testing
Threaded Bar SpecificationASTM A722 Threaded Bar Grade150
Threaded Bar TypeDeformed Rebar Size1"
Nut Specification for Threaded BarA29 System ManufacturerEaton Steel
Epoxy Coating ColorNA Threaded Bar ApplicationThreaded Bar
Coating StandardsUncoated Bar Heat Number(s)62139078
Nut Heat Number(s)NF15203286, 396574 Bar Lot NumberUnknown
Nut Lot Number26F1D, 26D5D Coupler Heat Number(s)N/A
Coupler GradeN/A

Test Details

DIME Sample ID: 2017-08-04-1
DIME Test ID: 2017-08-04-1-4
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A722-15: Standard Specification for High-Strength Steel Bars for Prestressed Concrete (Tensile)
Test Release Date: 2017-08-16

Test Results


Number of Threaded Bar Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 08/09/2017
UTM: 400KIP
Temperature: 72 F
NumSampleSizeMfg LotArea (sqin)Tensile Strength (psi)Stress at Offset (psi)Total Elongation (%)Reduction of area (%)CommentsTested By
14A722 1\" Threaded Bar & NutL96-126-170.8514578611880000A722 Threaded Bar and NutBrian

General comments (publicly viewable) (Max 1000 characters): A722 Threaded Bar and Nut
Test Graph
Source: Partner Data Point File
Test graph for the Sample

Test was verified on 8/9/2017