Summary for Test 2017-07-21-1-4
Test performed: ASTM A615-15Project Information
Project Identifiers | Project ID: 212352 DEA: 044K8004 |
---|---|
DIST-CO-RTE-PM | 04-SCL,SCL-35-10.5, 10.50, 9.5/10.5 |
Award Date | 04/28/2017 |
Closeout Date | 12/26/2019 |
Work Description | Construct SOLDIER PILE AND SOIL NAIL WALLS |
Location Description | IN SANTA CLARA COUNTY, NEAR LOS GATOS, AT 1.2 MILES NORTH OF LAS CUMBRES ROAD |
QA Service Level | 1 (Verified on 05/26/2017) |
Sample Information
Sample Taken Date | 07/21/2017 | Sample Unique Key | 1 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/25/2017 |
Sample type | Quality Assurance | A brief description of the sample | No 10 Gr 75 bar and hex nut |
The quantity of what the sample constitutes | unknown | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Ken | Last name of sampler or witnessed by | Varela |
Title of sampler | Associate Steel Inspector | Telephone number of sampler | 5624407716 |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Williams Form Eng | Transportation Laboratory (TL) Number | Unknown |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L08-072-17 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM5 - Threaded Bar | Production or Authorization Testing | Production Testing |
---|---|---|---|
Threaded Bar Specification | ASTM A615 | Threaded Bar Grade | 75 |
Threaded Bar Type | Deformed | Rebar Size | #10 |
Nut Specification for Threaded Bar | Grade 75 ATB | System Manufacturer | Williams Form Eng |
Epoxy Coating Color | NA | Threaded Bar Application | Threaded Bar |
Coating Standards | Uncoated | Bar Heat Number(s) | 100884127, DL16104196 |
Nut Heat Number(s) | 10H3D | Bar Lot Number | NA |
Nut Lot Number | NA | Coupler Heat Number(s) | NA |
Coupler Grade | NA |
Test Details
DIME Sample ID: 2017-07-21-1
DIME Test ID: 2017-07-21-1-4
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A615-15: Standard Specification for Deformed and Plain Carbon-Steel Bars for Concrete Reinforcement (Tensile)
Test Release Date: 2017-08-02
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 07/25/2017
UTM: 400KIP
Temperature: 72 F
Num | Sample | Size | Mfg Lot | Area (sqin) | Tensile Strength (psi) | Stress at Offset (psi) | Total Elongation (%) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|---|
1 | 4 | #10 Bar Heat #DL16104196, Nut Heat #10H5D | L0807217 | 1.27 | 119404 | 83396 | 0 | A615 Bar & Nut | Fred |
General comments (publicly viewable) (Max 1000 characters): A615 Bar & Nut
Test Graph
Source: Partner Data Point FileTest was verified on 7/26/2017 ✔