Test 2017-07-21-2-3 (CTM 670-December 2013) Summary

Project Information
Project IdentifiersProject ID: 7428
DEA: 07215944
EFIS: 0700001834
DIST-CO-RTE-PM07-LA-5-4.0/5.9
Work DescriptionRECONSTRUCT AND WIDEN FREEWAY AND UNDERCROSSING STRUCTURES.
Location DescriptionLOS ANGELES COUNTY IN NORWALK FROM 0.4 MILE SOUTH OF SAN ANTONIO DRIVE UNDERCROSSING TO 0.7 MILE NORTH OF PIONEER BOULEVARD UNDERCROSSING
Sample Information
Sample Taken Date7/21/2017 Sample Unique Key2
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing7/24/2017
Sample typeQuality Assurance A brief description of the sample4 feet one and a half inch Welded Hoops
The quantity of what the sample constitutes1 set of 4 From where was the sample collectedFabricator
First name of sampler or witnessed byGeorge Last name of sampler or witnessed byLujan
Title of samplerQAI Laboratory sample identificationUnknown
The fabricator/manufacturer/facility nameRKR Steel Welding Transportation Laboratory (TL) NumberQC TL101 C950653
Inspector Lot Number from the Transportation Laboratory (TL) FormL36-014-17 Structure unique identifierNot set
Structure nameNot set
Material Information
Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingRetest
Service or UltimateUltimate Rebar Heat Number(s)65026858
Hoop Manufacturer Lot Number(s)5 Material Standard CodeASTM A706
Material Grade60 Rebar Size8
Diameter of Hoop4'-1.5" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerGerdau
Welding CompanyRKR Steel Welding Coating StandardsUncoated
Weld TypeFlash Welded
Test Details
DIME Sample ID: 2017-07-21-2
DIME Test ID: 2017-07-21-2-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2017-08-01
Test Results

Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 07/25/2017
UTM:400KIP
Temperature:72 F
NumSampleMfg. Lot Number(s)SizeArea (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
135A#8/25mm0.797590096080Bar BrokeBrian

General comments (publicly viewable) (Max 1000 characters): Bar Broke; OK Necking
Test Graph
Source: Partner Data Point File
Test graph for the Sample

Test was verified on 07/25/2017