Summary for Test 2017-07-18-19-1

Test performed: ASTM F606-14

Project Information

Project IdentifiersProject ID: 211948
DEA: 073W2204
EFIS: 0716000011
DIST-CO-RTE-PM07-LA-210-R0.0/R15.8
Award Date02/15/2017
Closeout Date08/28/2019
Work DescriptionREPLACE BRIDGE APPROACH SLABS AND REHABILITATE DECKS.
Location DescriptionLOS ANGELES COUNTY IN LOS ANGELES AND GLENDALE FROM NORTH CONNECTOR OVERCROSSING TO HONOLULU AVENUE UNDERCROSSING
QA Service Level1 (Verified on 04/20/2017)

Sample Information

Sample Taken Date07/18/2017 Sample Unique Key19
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/21/2017
Sample typeQuality Assurance A brief description of the sampleA307A Threaded Rod
The quantity of what the sample constitutes1 From where was the sample collectedFabricator
First name of sampler or witnessed byGeorge Last name of sampler or witnessed byLujan
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameUlmer Industries Transportation Laboratory (TL) NumberC940652
Inspector Lot Number from the Transportation Laboratory (TL) FormL3600917 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)
Heat Number(s)405414 Nut Mfg. Lot Number(s)
Washer Mfg. Lot Number(s) Bolt SpecificationA307A
Bolt Length(s)3'-8" Nut SpecificationNA
Washer SpecificationNA FinishA153 / F2329
Diameter/Size.750 Bolt Mfg. Lot Number1
Rocap Test Requirement(s) Lubricant Requirements(s)

Test Details

DIME Sample ID: 2017-07-18-19
DIME Test ID: 2017-07-18-19-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Test Release Date: 2017-07-31

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 07/24/2017
UTM: 400KIP
Temperature: 72
NumSampleSizeArea (in^2)Peak Load (lbf)Peak Load (kN)Tensile Strength (psi)Stress at Offset (psi)Load at Offset (lbf)Comments
11AA307 A .750\" x 44\" threaded Rod0.33425620113767076461321581A307 A Threaded Stud

General comments (publicly viewable) (Max 1000 characters): A307 A Threaded Stud
Test Graph
Source: Partner Data Point File

Test was verified on 7/24/2017