Summary for Test 2017-07-14-3-2
Test performed: ASTM F606-14aProject Information
Project Identifiers | Project ID: 88888 DEA: SMTL-STOCK EFIS: SMTL-STOCK |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for SMTL stock material. Object Code: 1025. J2 DEA: 912680. |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 07/14/2017 | Sample Unique Key | 3 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/14/2017 |
Sample type | Verification | A brief description of the sample | 7/8 x 18 A449 HDG w/nut and washer |
The quantity of what the sample constitutes | 5 ea | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | David | Last name of sampler or witnessed by | Flygare |
Title of sampler | CA METS QA Inspector | Telephone number of sampler | 801-669-2984 |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | UIS | Transportation Laboratory (TL) Number | Unknown |
Inspector Lot Number from the Transportation Laboratory (TL) Form | B76-094-17 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | none |
---|---|---|---|
Heat Number(s) | bolt 62141302, washer 41542750, nut 10392030 | Nut Mfg. Lot Number(s) | 16-40-004 |
Washer Mfg. Lot Number(s) | D2181 | Bolt Specification | A449 |
Bolt Length(s) | 18 | Nut Specification | A563-DH |
Washer Specification | F436 | Finish | HDG |
Diameter/Size | 7/8" x 18" | Bolt Mfg. Lot Number | 29097 |
Rocap Test Requirement(s) | none | Lubricant Requirements(s) |
Test Details
DIME Sample ID: 2017-07-14-3
DIME Test ID: 2017-07-14-3-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2017-07-31
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 07/20/2017
UTM: 400KIP
Temperature: 72 F
Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By |
---|---|---|---|---|---|---|---|
1 | 1B | B7609417 | 7/8\" | 71303 | 317.17 | Nut Proof Load | Fred |
General comments (publicly viewable) (Max 1000 characters): Nut Proof Load
Test Graph
Source: Partner Data Point FileTest was verified on 7/24/2017 ✔