Summary for Test 2017-07-13-5-1

Test performed: ASTM A615-15

Project Information

Project IdentifiersProject ID: 211931
DEA: 043G6414
EFIS: 0416000348
DIST-CO-RTE-PM04-NAP-29-37.0
Award Date03/17/2017
Closeout Date04/22/2020
Work DescriptionSCOUR REPLACE BRIDGE
Location DescriptionNAPA COUNTY IN CALISTOGA AT NAPA RIVER BRIDGE
QA Service Level1 (Verified on 02/15/2017)

Sample Information

Sample Taken Date07/13/2017 Sample Unique Key5
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/17/2017
Sample typeQuality Assurance A brief description of the sampleWilliams Thread Bars
The quantity of what the sample constitutes2 From where was the sample collectedJob Site
First name of sampler or witnessed byChris Last name of sampler or witnessed byMoulton
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameWilliams Forms Transportation Laboratory (TL) NumberC647232
Inspector Lot Number from the Transportation Laboratory (TL) FormL7300517 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Threaded Bar Production or Authorization TestingProduction Testing
Threaded Bar SpecificationASTM A615 Threaded Bar Grade75
Threaded Bar TypeDeformed Rebar Size#9
Nut Specification for Threaded Bar75 System ManufacturerWilliams Form
Epoxy Coating ColorPurple Threaded Bar ApplicationThreaded Bar
Coating StandardsASTM A934 epoxy Bar Heat Number(s)100786966
Nut Heat Number(s)9H5D Bar Lot NumberUnknown
Nut Lot NumberUnknown Coupler Heat Number(s)9H2D
Coupler Grade75

Test Details

DIME Sample ID: 2017-07-13-5
DIME Test ID: 2017-07-13-5-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A615-15: Standard Specification for Deformed and Plain Carbon-Steel Bars for Concrete Reinforcement (Tensile)
Test Release Date: 2017-07-27

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 07/19/2017
UTM: 400KIP
Temperature: 72 F
NumSampleSizeMfg LotArea (sqin)Tensile Strength (psi)Stress at Offset (psi)Total Elongation (%)CommentsTested By
11#9 Williams Bar , Nut ##9H5D, Coupler #9H2DL73005171128072993480A615 Bar, Nut & CouplerFred

General comments (publicly viewable) (Max 1000 characters): A615 Bar, Nut & Coupler
Test Graph
Source: Partner Data Point File

Test was verified on 7/20/2017