Summary for Test 2017-07-11-1-3

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 209146
DEA: 06471504
EFIS: 0600000464
COOP: 061549
DIST-CO-RTE-PM06-TUL-99-39.6/41.3
Award Date02/24/2017
Closeout Date03/03/2020
Work DescriptionRECONSTRUCT INTERCHANGE WITH NEW PUMPING PLANT.
Location DescriptionTULARE COUNTY AT GOSHEN FROM 0.9 MILE NORTH OF ROUTE 99/198 WEST SEPARATION TO 0.2 MILE NORTH OF NORTH GOSHEN OVERHEAD
QA Service Level1 (Verified on 10/08/2013)

Sample Information

Sample Taken Date07/11/2017 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/12/2017
Sample typeQuality Assurance A brief description of the sampleFlash Welded Rebar Hoops
The quantity of what the sample constitutes12 From where was the sample collectedFabricator
First name of sampler or witnessed byGreg Last name of sampler or witnessed byJohnston
Title of samplerQA Telephone number of sampler9165247768
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameCMC Rbar Transportation Laboratory (TL) NumberUnknown
Inspector Lot Number from the Transportation Laboratory (TL) FormL5314517 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingAuthorization Testing
Service or UltimateUltimate Rebar Heat Number(s)4066804 4067060
Hoop Manufacturer Lot Number(s)1, 3 Material Standard CodeASTM A706
Material Grade60 Rebar Size6, 7
Diameter of Hoop3' 6", 3' 8" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerCMC Rebar
Welding CompanyCMC Rebar (Etiwanda) Coating StandardsUncoated
Weld TypeFlash Welded

Test Details

DIME Sample ID: 2017-07-11-1
DIME Test ID: 2017-07-11-1-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2017-07-27

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 07/13/2017
UTM: 400KIP
Temperature: 72 F
NumSampleMfg. Lot Number(s)SizeArea (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
131#6/19mm0.444211095700Bar BrokeFred

General comments (publicly viewable) (Max 1000 characters): Bar Broke; OK Necking
Test Graph
Source: Partner Data Point File
Test graph for the Sample

Test was verified on 7/20/2017