Test 2017-07-06-1-4 (ASTM F606-14a) Summary

Project Information
Project IdentifiersProject ID: 3807
DEA: 07121844
EFIS: 0700000117
DIST-CO-RTE-PM07-LA-5-42.8/47.3
Work DescriptionCONSTRUCT HOV LANES, RETAINING WALLS AND SOUND WALLS.
Location DescriptionLOS ANGELES COUNTY IN LOS ANGELES, GLENDALE, AND BURBANK FROM ROUTE 5/134 SEPARATION TO MAGNOLIA BOULEVARD OVERCROSSING
Sample Information
Sample Taken Date7/6/2017 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing7/10/2017
Sample typeQuality Assurance A brief description of the sampleA325 HDG Rocap Assembiy
The quantity of what the sample constitutes375 From where was the sample collectedSource
First name of sampler or witnessed byKevin Last name of sampler or witnessed byChurchill
Title of samplerQAI Laboratory sample identificationUnknown
The fabricator/manufacturer/facility nameSt Louis Screw Bolt Transportation Laboratory (TL) NumberUnknown
Inspector Lot Number from the Transportation Laboratory (TL) FormL02-052-17 Structure unique identifierNot set
Structure nameNot set
Material Information
Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)TT0086195
Heat Number(s)20372930 Nut Mfg. Lot Number(s)24877
Washer Mfg. Lot Number(s)D3436 Bolt SpecificationA325
Bolt Length(s)3-3/4" Nut SpecificationA563
Washer SpecificationF436 FinishHDG
Diameter/Size7/8" Bolt Mfg. Lot NumberBM0416
Rocap Test Requirement(s) Lubricant Requirements(s)YES
Test Details
DIME Sample ID: 2017-07-06-1
DIME Test ID: 2017-07-06-1-4
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2017-07-19
Test Results

Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 07/11/2017
UTM:400KIP
Temperature:72 F
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)CommentsTested By
12AL02-052-177/8\"71061316.1Nut Proof LoadBrian

General comments (publicly viewable) (Max 1000 characters): Nut Proof Load
Test Graph
Source: Partner Data Point File

Test was verified on 07/12/2017