Summary for Test 2017-05-31-1-1

Test performed: CONCLP 3-16

Project Information

Project IdentifiersProject ID: 211935
DEA: 101F2604
EFIS: 1016000081
DIST-CO-RTE-PM10-CAL,MER-4,33,59,99,152-Var
Award Date02/17/2017
Closeout Date01/24/2018
Work DescriptionREPLACE JOINT SEALS, TREAT BRIDGE DECKS, AND REPLACE APPROACH SLABS.
Location DescriptionCALAVERAS AND MERCED COUNTIES AT VARIOUS LOCATIONS
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date05/31/2017 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/31/2017
Sample typeQuality Control A brief description of the sample1 gallon can
The quantity of what the sample constitutes1 gallon can From where was the sample collectedSource
First name of sampler or witnessed byChris Last name of sampler or witnessed byNunes
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameKwik bond and Reichhold Transportation Laboratory (TL) NumberSacramento Caltrans lab
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypePolyester Mfg. Lot Number(s)1054553
Batch number1054553 Mix number1054553

Test Details

DIME Sample ID: 2017-05-31-1
DIME Test ID: 2017-05-31-1-1
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: CONCLP 3-16: Polyester Resin
Test Release Date: 2017-07-10

Test Results


Input Type: Calculated
Tester's full name: Mike Mullins
Date of test: 07/10/2017
Viscosity ASTM D 2196, RVT, No. 1 spindle 75 to 200 cps @ 20 RPM, 77°F: 100 cps
Specific gravity ASTM D 1475 1.05 to 1.10 @ 77°F: 1.08
Conditioning (18/25/50 + 5/70) Elogation ASTM D 638, minimum 35%: 58.29 %
Tensile Strength ASTM D 638 Type 1 @ 0.45 in/min, minimum 2500 psi: 3196 psi
Styrene ASTM D 2369 40% to 50 %: 46 %
PCC - SSD bond strength CTM 551 500 psi minimun @ 24 hours: 618 psi
Static Volatile Emissions, SCAQMD 309-91, maximum loss 1.0 grams: 0.2 grams
General comments (publicly viewable) (Max 1000 characters): accepted suppliers Q.C. results

Test was verified on 7/10/2017