Test 2017-05-17-8-1 (CONCLP 3-16) Summary

Project Information
Project IdentifiersProject ID: 7613
DEA: 071218W4
EFIS: 0700021119
DIST-CO-RTE-PM07-LA-5-29.4/31.6
Work DescriptionREALIGN ROUTE 5 AND RAILROAD TRACKS AND RECONFIGURE ON- AND OFF-RAMPS.
Location DescriptionLOS ANGELES COUNTY IN BURBANK FROM WEST MAGNOLIA BOULEVARD OVERCROSSING TO 0.3 MILE NORTH OF BUENA VISTA STREET/WINONA AVENUE UNDERCROSSING
Sample Information
Sample Taken Date5/17/2017 Sample Unique Key8
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing5/17/2017
Sample typeQuality Control A brief description of the sample1 gallon can
The quantity of what the sample constitutes2 tankers From where was the sample collectedSource
First name of sampler or witnessed byChris Last name of sampler or witnessed byNunes
Title of samplerUnknown Laboratory sample identificationUnknown
The fabricator/manufacturer/facility nameKwik bond and Reichhold Transportation Laboratory (TL) NumberSacramento Caltrans lab
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierNot set
Structure nameNot set
Material Information
Material TypePolyester Mfg. Lot Number(s)1050701
Batch number1050701 Mix number1050701
Test Details
DIME Sample ID: 2017-05-17-8
DIME Test ID: 2017-05-17-8-1
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: CONCLP 3-16: Polyester Resin
Test Release Date: 2017-07-10
Test Results

Input Type: Calculated
Tester's full name: Mike Mullins
Date of test: 07/10/2017
Viscosity ASTM D 2196, RVT, No. 1 spindle 75 to 200 cps @ 20 RPM, 77°F: 93 cps
Specific gravity ASTM D 1475 1.05 to 1.10 @ 77°F: 1.08
Conditioning (18/25/50 + 5/70) Elogation ASTM D 638, minimum 35%: 60.75 %
Tensile Strength ASTM D 638 Type 1 @ 0.45 in/min, minimum 2500 psi: 3192 psi
Styrene ASTM D 2369 40% to 50 %: 46.09 %
PCC - SSD bond strength CTM 551 500 psi minimun @ 24 hours: 586 psi
Static Volatile Emissions, SCAQMD 309-91, maximum loss 1.0 grams: 0.2 grams
General comments (publicly viewable) (Max 1000 characters): accepted suppliers Q.C. results

Test was verified on 07/10/2017