Summary for Test 2017-06-06-9-1
Test performed: ASTM C39-10Project Information
Project Identifiers | Project ID: 211853 DEA: 042G8904 EFIS: 0400021259 |
---|---|
DIST-CO-RTE-PM | 04-MRN-1-8.0 |
Award Date | 02/09/2017 |
Closeout Date | 12/22/2017 |
Work Description | SOLDIER PILE WALL WITH TIEBACKS AND EMBANKMENT CONFINED SYSTEM. |
Location Description | MARIN COUNTY NEAR MUIR BEACH AT 2.1 MILES NORTH OF MUIR WOODS ROAD |
QA Service Level | 1 (Verified on 03/15/2017) |
Sample Information
Sample Taken Date | 06/06/2017 | Sample Unique Key | 9 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 06/16/2017 |
Sample type | Quality Assurance | A brief description of the sample | 6x12 concrete cylinders |
The quantity of what the sample constitutes | 2 6x12 concrete cylinders | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Janine | Last name of sampler or witnessed by | Marr |
Title of sampler | Transportation Engineer | Telephone number of sampler | 1-510-385-6764 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Shamrock Materials | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name | Retaining Wall 8 |
Material Information
Material Type | Concrete | The concrete mix design number | 4201a |
---|---|---|---|
The truck number from where the sample was collected | 1808 | The batch plant ticket number from where the sample was collected | 124359 |
Concrete batch plant | The fabricator/manufacturer designation for the sample | ||
A detailed description of where the material sample was collected | truck chute | Where the material sample would have been placed if not sampled | soldier pile wall |
From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2017-06-06-9
DIME Test ID: 2017-06-06-9-1
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2017-07-05
Test Results
Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: Bang
Date of test: 07/05/2017
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 6.01 in
Average diameter of cylinder 2: 5.99 in
Maximum load on cylinder 1: 163133 lb
Maximum load on cylinder 2: 161596 lb
Type of fracture pattern of cylinder 1: 1
Type of fracture pattern of cylinder 2: 1
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: no data
Age of specimen: 29 days
Cross sectional area of cylinder 1: 28.37 in^2
Cross sectional area of cylinder 2: 28.18 in^2
Compressive strength of cylinder 1: 5750.2 psi
Compressive strength of cylinder 2: 5734.4 psi
Compressive strength (to nearest 10 psi): 5740 psi
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Partner Data Point FileTest graph for Cylinder Code 1 of 2
Source: Partner Data Point File
Test graph for Cylinder Code 2 of 2
Test was verified on 7/5/2017 ✔