Test 2017-06-19-3-2 (ASTM C109-11) Summary

Project Information
Project IdentifiersProject ID: 88888
DEA: STOCK
EFIS: STOCK
DIST-CO-RTE-PM59---
Work DescriptionSpecial project for SMTL stock material. Object Code: 1025. J2 DEA: 912680.
Location DescriptionNot set
Sample Information
Sample Taken Date6/19/2017 Sample Unique Key3
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing6/12/2017
Sample typeAnnual Source Testing A brief description of the sampleSilica Fume
The quantity of what the sample constitutes1 Bucket From where was the sample collectedSource
First name of sampler or witnessed byUnknown Last name of sampler or witnessed byUnknown
Title of samplerUnknown Laboratory sample identificationCM175718
The fabricator/manufacturer/facility nameRED Industries Transportation Laboratory (TL) NumberUnknown
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierNot set
Structure nameNot set
Material Information
Material TypeCementitious BrandRED Industrial Products
MillMississippi Silicon Type of Cementitious MaterialSilica Fume
Test Details
DIME Sample ID: 2017-06-19-3
DIME Test ID: 2017-06-19-3-2
Testing Lab: CT HQ - Sacramento Cement Testing Laboratory
Test Method: ASTM C109-11: Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50mm] Cube Specimens)
Test Release Date: 2018-08-08
Test Results

Will control cubes be used per ASTM C311?: yes
Input Type: Measured
Tester's full name: TTO
Date of test: 06/28/2017
Age of specimen: 7 days
The amount of flow (In percent): 108 %
The amount of water used (In percent): 48.3 %
Maximum load of 1st specimen (lb): 21753 lb
Maximum load of 2nd specimen (lb): 21326 lb
Maximum load of 3rd specimen (lb): 23105 lb
Cross sectional area loaded of 1st specimen (sq. inch): 4 in^2
Cross sectional area loaded of 2nd specimen (sq. inch): 4 in^2
Cross sectional area loaded of 3rd specimen (sq. inch): 4 in^2
Average Compressive strength (to nearest 10 psi) control group: 4224 psi
Compressive strength of 1st specimen (psi): 5438 psi
Compressive strength of 2nd specimen (psi): 5332 psi
Compressive strength of 3rd specimen (psi): 5776 psi
Average Compressive strength (to nearest 10 psi): 5520 psi
Strength Activity Index of Portland Cement per ASTM C311:131
General comments (publicly viewable) (Max 1000 characters): 7 Day Break
Test Graph
Source: Partner Data Point File
Test graph for Specimen 1 of 3

Source: Partner Data Point File
Test graph for Specimen 2 of 3

Source: Partner Data Point File
Test graph for Specimen 3 of 3

Test was verified on 08/08/2018