Summary for Test 2017-06-20-3-3

Test performed: ASTM F606-14a

Project Information

Project IdentifiersProject ID: 211588
DEA: 030F3104
EFIS: 0300000078
DIST-CO-RTE-PM03-ED-49-23.6/24.5
Award Date12/12/2016
Closeout Date01/08/2019
Work DescriptionREPLACE BRIDGE.
Location DescriptionEL DORADO COUNTY NEAR COLOMA FROM 0.1 MILE EAST OF MARSHALL ROAD TO 0.3 MILE EAST OF LOTUS ROAD
QA Service Level1 (Verified on 10/19/2016)

Sample Information

Sample Taken Date06/20/2017 Sample Unique Key3
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/20/2017
Sample typeVerification A brief description of the sample3/4 x 5 1/2 A325 bolt,nut,washer
The quantity of what the sample constitutes9 and 12 From where was the sample collectedFabricator
First name of sampler or witnessed byDavid Last name of sampler or witnessed byFlygare
Title of samplerCA METS QA Inspector Telephone number of sampler(801) 669-2984
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameUIS Transportation Laboratory (TL) NumberUnknown
Inspector Lot Number from the Transportation Laboratory (TL) FormB76-063-17 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)n/a
Heat Number(s)Bolt NF16100930, nut 20388020, FW 542102 Nut Mfg. Lot Number(s)Decker 15-40-006
Washer Mfg. Lot Number(s)D2020 Bolt SpecificationA325
Bolt Length(s)5 1/2" Nut SpecificationA563-DH
Washer SpecificationF436 FinishHDG
Diameter/Size3/4" x 5 1/2" Bolt Mfg. Lot NumberG8505
Rocap Test Requirement(s)none Lubricant Requirements(s)

Test Details

DIME Sample ID: 2017-06-20-3
DIME Test ID: 2017-06-20-3-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2017-07-05

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 06/28/2017
UTM: 400KIP
Temperature: 71 F
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)CommentsTested By
13AB76-063-177/8\"70655314.29Nut Proof LoadBrian

General comments (publicly viewable) (Max 1000 characters): Nut Proof Load
Test Graph
Source: Partner Data Point File

Test was verified on 6/28/2017