Summary for Test 2017-06-21-4-1
Test performed: CTM 670-December 2013Project Information
Project Identifiers | Project ID: 211595 DEA: 060H6424 EFIS: 0614000266 |
---|---|
DIST-CO-RTE-PM | 06-KER-99-49.6 |
Award Date | 11/03/2016 |
Closeout Date | 08/29/2018 |
Work Description | CONSTRUCT PEDESTRIAN OVERCROSSING BRIDGE. |
Location Description | KERN COUNTY IN MCFARLAND AT KERN AVENUE PEDESTRIAN OVERCROSSING |
QA Service Level | 1 (Verified on 10/07/2016) |
Sample Information
Sample Taken Date | 06/21/2017 | Sample Unique Key | 4 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/22/2017 |
Sample type | Quality Assurance | A brief description of the sample | Barsplice Griptwist coupler |
The quantity of what the sample constitutes | 4 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | U | Last name of sampler or witnessed by | b |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | BarSplice Gerdau | Transportation Laboratory (TL) Number | C773755 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | N/A | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM5 - Couplers | Production or Authorization Testing | Production Testing |
---|---|---|---|
Service or Ultimate | Ultimate | Material Standard Code | ASTM A706 |
Material Grade | 60 | Rebar Manufacturer | Gerdau |
Coupler Manufacturer | BarSplice | Intermediate Assembler or Fabricator | Unknown |
Rebar Size | 10 | Coupler Model | Taper Grip-Twist |
Coating Standards | Uncoated | Shape of Rebar | Straight |
Rebar Hoop Diameter | Unknown | Rebar Hoop Fabricator | Unknown |
Coupler Component Heat/Lot Number(s) | A164888 | Rebar Heat Number(s) | 65026802 |
Rebar Size 2 | Not set | Coupler Unique ID | Not set |
Test Details
DIME Sample ID: 2017-06-21-4
DIME Test ID: 2017-06-21-4-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Test Release Date: 2017-06-29
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 06/22/2017
UTM: 2000KIP
Halo ID: Small
Temperature: 72 F
Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Slip (inch) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|---|
1 | 1 | #10/32mm | 1.27 | -0.0015 | 115136 | 90658 | necking okay | Brian |
General comments (publicly viewable) (Max 1000 characters): necking okay
Test Graph
Source: Partner Data Point FileTest graph for the Sample
Test was verified on 6/22/2017 ✔