Test 2017-05-01-2-1 (CONCLP 3-16) Summary

Project Information
Project IdentifiersProject ID: 211590
DEA: 030H11U4
EFIS: 0316000035
DIST-CO-RTE-PM03-SAC-51,160-4.0/4.3,R44.4/47.0
Work DescriptionPAVE HMA, REPLACE GUARD RAIL & PULL BOXES, POLYESTER BRIDGE OVERLAY.
Location DescriptionSACRAMENTO COUNTY IN SACRAMENTO FROM AMERICAN RIVER BRIDGE TO 0.3 MILE NORTH OF ARDEN WAY UNDERCROSSING
Sample Information
Sample Taken Date5/1/2017 Sample Unique Key2
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing5/1/2017
Sample typeQuality Control A brief description of the sample1 gallon can
The quantity of what the sample constitutes2 tankers From where was the sample collectedSource
First name of sampler or witnessed byChris Last name of sampler or witnessed byNunes
Title of samplerUnknown Laboratory sample identificationUnknown
The fabricator/manufacturer/facility nameKwik bond and Reichhold Transportation Laboratory (TL) NumberSacramento Caltrans lab
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierNot set
Structure nameNot set
Material Information
Material TypePolyester Mfg. Lot Number(s)1046759
Batch number1046759 Mix number1046759
Test Details
DIME Sample ID: 2017-05-01-2
DIME Test ID: 2017-05-01-2-1
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: CONCLP 3-16: Polyester Resin
Test Release Date: 2017-05-25
Test Results

Input Type: Calculated
Tester's full name: Mike Mullins
Date of test: 05/25/2017
Viscosity ASTM D 2196, RVT, No. 1 spindle 75 to 200 cps @ 20 RPM, 77°F: 104 cps
Specific gravity ASTM D 1475 1.05 to 1.10 @ 77°F: 1.08
Conditioning (18/25/50 + 5/70) Elogation ASTM D 638, minimum 35%: 62 %
Tensile Strength ASTM D 638 Type 1 @ 0.45 in/min, minimum 2500 psi: 3133 psi
Styrene ASTM D 2369 40% to 50 %: 46.1 %
PCC - SSD bond strength CTM 551 500 psi minimun @ 24 hours: 572 psi
Static Volatile Emissions, SCAQMD 309-91, maximum loss 1.0 grams: 0.14 grams
General comments (publicly viewable) (Max 1000 characters): accepted on Q.C. results

Test was verified on 05/25/2017