Summary for Test 2017-05-19-1-3

Test performed: ASTM A884-14

Project Information

Project IdentifiersProject ID: 210914
DEA: 07306204
EFIS: 0714000151
DIST-CO-RTE-PM07-LA-91-R11.3/R20.7
Award Date01/13/2016
Closeout Date04/09/2019
Work DescriptionROADWAY REHABILITATION
Location DescriptionIN LOS ANGELES COUNTY, BETWEEN I-710 IN LONG BEACH AND 183RDSTREET IN CERRITOS
QA Service Level1 (Verified on 10/14/2016)

Sample Information

Sample Taken Date05/19/2017 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/22/2017
Sample typeQuality Assurance A brief description of the sampleEpoxy Coated Dowel Basket
The quantity of what the sample constitutes2 From where was the sample collectedSource
First name of sampler or witnessed byRichard Last name of sampler or witnessed byBettencourt
Title of samplerCT METS QA INSPECTOR Telephone number of sampler5594413230
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameDayton Superior Modesto Transportation Laboratory (TL) NumberUnknown
Inspector Lot Number from the Transportation Laboratory (TL) FormS25-080-17 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM7 - Epoxy Coated Dowels Dowel Metal Heat Number17102445
Dowel Epoxy Batch Number7396024285 Dowel Coating SpecificationASTM A775
Dowel Size1.5 in Dowel Coating ColorGreen
Dowel ManufacturerDayton Superior Dowel CoaterDayton Superior
Release Number1320744-1 Quality Assurance CodeUnknown
Rebar Size (#)

Test Details

DIME Sample ID: 2017-05-19-1
DIME Test ID: 2017-05-19-1-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A884-14: Standard Specification for Epoxy-Coated Steel Wire and Welded Wire Reinforcement (Epoxy Coating Thickness)
Test Release Date: 2017-05-31

Test Results


Input Type: Measured
Tester's full name: Arnold Viken
Date of test: 05/23/2017
Lower spec. limit LSL: 7 mils
Upper spec. limit USL: 40 mils
First Bar Side 1 mean value: 10.5 mils
First Bar Side 2 mean value: 10.97 mils
Second Bar Side 1 mean value: 11.43 mils
Second Bar Side 2 mean value: 10.64 mils
First Bar Mean: 10.74 mils
Second Bar Mean: 11.04 mils
Total mean value: 10.89 mils
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 5/24/2017