Summary for Test 2017-05-08-1-10

Test performed: ASTM A416-15

Project Information

Project IdentifiersProject ID: 211690
DEA: 042A3204
EFIS: 0400000817
DIST-CO-RTE-PM04-NAP-121-9.2/9.4
Award Date12/01/2016
Closeout Date01/23/2019
Work DescriptionROADWAY WIDENING, BRIDGE REPLACEMENT, CREEK GRADING
Location DescriptionNAPA COUNTY IN NAPA AT SILVERADO TRAIL ROAD
QA Service Level1 (Verified on 01/03/2017)

Sample Information

Sample Taken Date05/08/2017 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing05/09/2017
Sample typeQuality Assurance A brief description of the sample0.6 L/R 7 wire strand
The quantity of what the sample constitutes1 coil each From where was the sample collectedFabricator
First name of sampler or witnessed byStacey Last name of sampler or witnessed byDavis
Title of samplerQAI Telephone number of sampler5624806984
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameKie-Con Antioch Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM4 - Prestressing Strand Comments
Reel/Coil/Pack Number(s)S333792-6, S333795-6, S333797-6, S333798-6, S377587-5, S333778-6, S333784-6, S333785-6, S333788-6, S333796-6, S377590-1, S377617-5, S377573-1 Number of Coils13
Group NumberUnknown Strand Diameter.6 in
Grade270 Strand SpecificationASTM A 416
Heat Number(s)S0286190, S053616, S0286198, S026197, S0286193, S0286687, S0286194 Mfg. Lot Number(s)N/A
Manufacturer(s)Sumiden Wire

Test Details

DIME Sample ID: 2017-05-08-1
DIME Test ID: 2017-05-08-1-10
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Test Release Date: 2017-05-17

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 05/10/2017
UTM: 120KIP
Temperature: 72 F
Extensometers: E88766
NumHeat NumberCoilArea (sqin)Peak Load (lbf)Load at EUL (lbf)Chord Modulus (Msi)Elongation (in)Tested By
1S0513616S333795-60.215601775481428.11.82Brian

General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Partner Data Point File
Test graph for the Sample

Test was verified on 5/10/2017