Summary for Test 2017-04-27-5-3

Test performed: ASTM D624-00-re12

Project Information

Project IdentifiersProject ID: 211260
DEA: 072159U4
EFIS: 0715000160
DIST-CO-RTE-PM07-LA,ORA-5-0.0/1.5, 44.3/44.4
Award Date05/27/2016
Closeout Date08/01/2023
Work DescriptionCONSTRUCT HOV LANES AND MIX FLOW LANES.
Location DescriptionLOS ANGELES AND ORANGE COUNTIES IN BUENA PARK, LA MIRADA, CERRITOS AND SANTA FE SPRINGS FROM ARTESIA BOULEVARD UNDERCROSSING TO NORTH FORK COYOTE CREEK
QA Service Level1 (Verified on 03/16/2016)

Sample Information

Sample Taken Date04/27/2017 Sample Unique Key5
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/03/2017
Sample typeQuality Assurance A brief description of the sampleBearing Pad
The quantity of what the sample constitutes4 From where was the sample collectedManufacturer
First name of sampler or witnessed byPete Last name of sampler or witnessed byEtcheverry
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameScougal Rubber Transportation Laboratory (TL) NumberC925885
Inspector Lot Number from the Transportation Laboratory (TL) FormS3805117 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM1 - Elastomeric Bearing Pad Mfg. Lot Number(s)15538-2, 3, 4, 5, 6, 7, 8, 16
Material/Compound/Elastomer IDNA Samples Representing4
Description (size)Various Size CommentsUnknown
Description (Number of Shims)4 - 8 Type of Bearing PadSteel
Description (Thickness of Shims)14 gage Manufacturer(s)Scougal Rubber
Batch NumberNA

Test Details

DIME Sample ID: 2017-04-27-5
DIME Test ID: 2017-04-27-5-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM D624-00-re12: Standard Test Method for Tear Strength of Conventional Vulcanized Rubber and Thermoplastic Elastomers
Test Release Date: 2017-05-18

Test Results


Number of specimens tested: 3
Input Type: Measured
Tester's full name: Brian
Date of test: 05/08/2017
Humidity: 50 %
Temperature: 72 F
Sample 1 Median Thickness: 0.075 in
Sample 1 Tear Strength: 253.3 lbf / in
Sample 2 Median Thickness: 0.075 in
Sample 2 Tear Strength: 253.3 lbf / in
Sample 3 Median Thickness: 0.074 in
Sample 3 Tear Strength: 243.2 lbf / in
UTM: no data
Median of the Tear Strength Values: 253.3 lb/in
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Partner Data Point File
Test graph for Sample 1

Source: Partner Data Point File
Test graph for Sample 2

Source: Partner Data Point File
Test graph for Sample 3

Test was verified on 5/11/2017