Summary for Test 2017-04-25-3-9

Test performed: ASTM A416-15

Project Information

Project IdentifiersProject ID: 8196
DEA: 59912684
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work Description
Location Description
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date04/25/2017 Sample Unique Key3
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/28/2017
Sample typeQuality Assurance A brief description of the samplePrestressing Strand
The quantity of what the sample constitutes60 From where was the sample collectedManufacturer
First name of sampler or witnessed byDon Last name of sampler or witnessed byHiranaga
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameSumiden Wire Transportation Laboratory (TL) NumberUnknown
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM4 - Prestressing Strand CommentsUnknown
Reel/Coil/Pack Number(s) Number of Coils61
Group Number10859 Strand Diameter.620 in
Grade270 Strand SpecificationASTM A 416
Heat Number(s)S0288722 S0288882 S0288883 S0288884 S0288885 S0288890 S0290079 S0290085-2 S0514316 S0514316-2 S0518716 S0522816 S0523016 S0523116 S0543516 Mfg. Lot Number(s)na
Manufacturer(s)Sumiden Wire

Test Details

DIME Sample ID: 2017-04-25-3
DIME Test ID: 2017-04-25-3-9
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Test Release Date: 2017-05-11

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Arnold
Date of test: 05/03/2017
UTM: 120KIP
Temperature: 70 F
Extensometers: E88766
NumHeat NumberCoilArea (sqin)Peak Load (lbf)Load at EUL (lbf)Chord Modulus (Msi)Elongation (in)Tested By
1S0288885S333963-30.213594325591228.71.65Arnold

General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Partner Data Point File
Test graph for the Sample

Test was verified on 5/4/2017