Summary for Test 2017-04-11-9-1
Test performed: AGGLP SIEVE_ANALYSIS-1Project Information
Project Identifiers | Project ID: 212401 DEA: 101F4404 EFIS: 1016000092 |
---|---|
DIST-CO-RTE-PM | 10-SJ-99-5/5 |
Award Date | 01/09/2018 |
Closeout Date | 08/30/2023 |
Work Description | New building at paint maintenance facility |
Location Description | Paint maintenance facility |
QA Service Level | 1 (Verified on 03/23/2020) |
Sample Information
Sample Taken Date | 04/11/2017 | Sample Unique Key | 9 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/18/2017 |
Sample type | Quality Control | A brief description of the sample | Foundation study |
The quantity of what the sample constitutes | 1 bag | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Abubakarr | Last name of sampler or witnessed by | Barrie |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | 17SOIL-0090 | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | NA | Transportation Laboratory (TL) Number | C875102 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | Soil | The fabricator's/manufacturer's product name for the sample | Unknown |
---|---|---|---|
The fabricator/manufacturer designation for the sample | Unknown | A detailed description of where the material sample was collected | RC-17-001 |
Where the material sample would have been placed if not sampled | 0 TO 5 FT |
Test Details
DIME Sample ID: 2017-04-11-9
DIME Test ID: 2017-04-11-9-1
Testing Lab: CT HQ - Sacramento Aggregate Testing Laboratory
Test Method: AGGLP SIEVE_ANALYSIS-1: Soils for Corrosion Sieve Analysis
Test Release Date: 2017-05-05
Test Results
Input Type: Measured
Tester's full name: Phillip Montes
Date of test: 04/28/2017
Total mass of material in the sample: 9345 grams
Cumulative mass retained on the 2 in. sieve: 0 grams
Cumulative mass retained on the 1 1/2 in. sieve: 0 grams
Cumulative mass retained on the 1 in. sieve: 0 grams
Cumulative mass retained on the 3/4 in. sieve: 11 grams
Cumulative mass retained on the 1/2 in. sieve: 9 grams
Cumulative mass retained on the 3/8 in. sieve: 19 grams
Cumulative mass retained on the #4 sieve: 53 grams
Cumulative mass retained on the #8 sieve: 17 grams
Total sample mass passing the #4 sieve: 1617 grams
Total mass of fine material in the sample: 400 grams
Cumulative mass retained on the pan: 383 grams
Total cumulative mass of coarse aggregate: 92 grams
Total cumulative mass of fine aggregate: 400 grams
Sum of coarse and fine aggregate: 1709 grams
Percentage of coarse material: 5 %
Percentage of fine material: 95 %
Cumulative percent passing the 2 in. sieve: 100 %
Cumulative percent passing the 1 1/2 in. sieve: 100 %
Cumulative percent passing the 1 in. sieve: 100 %
Cumulative percent passing the 3/4 in. sieve: 99 %
Cumulative percent passing the 1/2 in. sieve: 99 %
Cumulative percent passing the 3/8 in. sieve: 98 %
Cumulative percent passing the #4 sieve: 95 %
Cumulative percent passing the #8 sieve: 91 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 4/28/2017 ✔