Summary for Test 2017-04-12-3-7

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 211794
DEA: 044G5104
EFIS: 0412000483
DIST-CO-RTE-PM04-SOL-80-31.4,32.6
Award Date01/20/2017
Closeout Date09/12/2019
Work DescriptionBRIDGE CONSTRUCTION
Location DescriptionSOLANO COUNTY IN AND NEAR VACAVILLE AT MERIDIAN ROAD OVERCROSSING AND AT MIDWAY ROAD OVERCROSSING
QA Service Level1 (Verified on 01/03/2017)

Sample Information

Sample Taken Date04/12/2017 Sample Unique Key3
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing04/24/2017
Sample typeRecertification A brief description of the sample Flash Welded Hoops
The quantity of what the sample constitutes10 From where was the sample collectedFabricator
First name of sampler or witnessed byRichard Last name of sampler or witnessed byBettencourt
Title of samplerQA Telephone number of sampler2092015432
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameCMC Rebar Tracy CA Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormS25-049-17 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingAuthorization Testing
Service or UltimateUltimate Rebar Heat Number(s)4061696
Hoop Manufacturer Lot Number(s)0 Material Standard CodeASTM A706
Material Grade60 Rebar Size8
Diameter of Hoop5'-0" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerCMC Arizona
Welding CompanyCMC Rebar (Tracy) Coating StandardsUncoated
Weld TypeFlash Welded

Test Details

DIME Sample ID: 2017-04-12-3
DIME Test ID: 2017-04-12-3-7
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical)
Test Release Date: 2017-05-23

Test Results


Number of Samples Tested: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 04/26/2017
UTM: 400KIP
Temperature: 72 F
NumSampleNumber of CyclesSizeMfg. Lot Number(s)Area (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
1Break-7100#8/25mmRick Bettencort, H & H Welder #H6020R0.7979351100444NECKING OKFred

General comments (publicly viewable) (Max 1000 characters): NECKING OK
Test Graph
Source: Partner Data Point File

Test was verified on 5/16/2017