Summary for Test 2017-04-18-2-1
Test performed: ASTM A970-15e1Project Information
Project Identifiers | Project ID: 210735 DEA: 071193U4 EFIS: 0713000007 |
---|---|
DIST-CO-RTE-PM | 07-LA-10-37.2/42.4 |
Award Date | 11/16/2015 |
Closeout Date | 07/11/2022 |
Work Description | CONSTRUCT HOV LANES, WIDEN BRIDGES, AND REALIGN RAMPS. |
Location Description | IN LA COUNTY FROM CITRUS STREET IN WEST COVINA TO ROUTE 57 IN POMONA |
QA Service Level | 1 (Verified on 03/07/2016) |
Sample Information
Sample Taken Date | 04/18/2017 | Sample Unique Key | 2 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/19/2017 |
Sample type | Quality Assurance | A brief description of the sample | HRC 120 End Anchors |
The quantity of what the sample constitutes | 8 | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Greg | Last name of sampler or witnessed by | Johnston |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | HRC CMC Rebar | Transportation Laboratory (TL) Number | C953704 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L5309117 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM5 - Headed Bars | Production or Authorization Testing | Production Testing |
---|---|---|---|
Rebar Heat Number(s) | 4064203 | Head Manufacturer Lot Number(s) | 1, 2 |
Rebar Size | #6 | Headed Bar Model Name | HRC 120 |
Size of Head | Reduced Size - 4x | Head Connection Type | Friction Weld |
Head Shape | Square | Rebar Manufacturer | CMC Rebar |
Head Manufacturer | HRC | Head Fabricator | CMC HRC |
Material Standard Code | ASTM A706 | Headed Bar Unique ID | Not set |
Test Details
DIME Sample ID: 2017-04-18-2
DIME Test ID: 2017-04-18-2-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Test Release Date: 2017-04-27
Test Results
Number of Headed Bar Samples: 6
Input Type: Measured
Tester's full name: Fred Saylor
Date of test: 04/20/2017
UTM: 67KIP
Temperature: 72 f
Num | Lot # | Area (sqin) | Peak Load (lbf) | Tensile Strength (psi) | Comments | Tested By |
---|---|---|---|---|---|---|
1 | 1 | .44 | 43069 | 97884 | OK Necking | Fred |
2 | 1 | .44 | 43131 | 98025 | OK Necking | Fred |
3 | 1 | .44 | 43310 | 98432 | OK Necking | Fred |
4 | 2 | .44 | 43014 | 97759 | OK Necking | Fred |
5 | 2 | .44 | 42980 | 97682 | OK Necking | Fred |
6 | 2 | .44 | 42925 | 97557 | OK Necking | Fred |
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 4/20/2017 ✔